Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisville |
---|---|
Assessment Year | 1996 |
Principal Product | Automative Exhaust Systems |
NAICS | n/a |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 90,000 |
Annual Production | 800,000 Pieces |
Production Hrs. Annual | 6,624 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $130,543 | 6,249,121 | kWh | $0.02 |
Electricity Demand | $96,145 | 13,799 | kW-months/year | $6.97 |
Electricity Fees | $2,136 | - | $ | - |
Natural Gas | $63,873 | 19,362 | MMBtu | $3.30 |
TOTAL ENERGY COSTS | $366,697 | |||
RECOMMENDED SAVINGS* | $523,089 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,589 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | By-product Production | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $297 Cost: $2,900 |
$185 | 8,792 | $112 | 16 | - | - | - | - | - | - |
$185 8,792 kWh |
$112 16 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $692 Cost: $20 |
$343 | 16,413 | $349 | 50 | - | - | - | - | - | - |
$343 16,413 kWh |
$349 50 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $517,500 Cost: $1,800 |
- | - | - | - | - | - | $(-172,500) | - | $690,000 | - |
- - kWh |
- - kW-months/year |
- - lb |
$(-172,500) - $ |
$690,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $3,275 Cost: - |
- | - | - | - | $3,275 | 54,000 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,275 54,000 lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $1,325 Cost: - |
- | - | - | - | $1,325 | 15,000 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,325 15,000 lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $523,089 Cost: $4,720 |
$528 | 25,205 | $461 | 66 | $4,600 | 69,000 | $(-172,500) | - | $690,000 | - | $528 25,205 kWh |
$461 66 kW-months/year |
$4,600 69,000 lb |
$(-172,500) - $ |
$690,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,589 Cost: $2,920 |
$528 | 25,205 | $461 | 66 | $4,600 | 69,000 | - | - | - | - | $528 25,205 kWh |
$461 66 kW-months/year |
$4,600 69,000 lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | By-product Production | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | By-product Production |