Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisville |
---|---|
Assessment Year | 1998 |
Principal Product | Galvanized Corrugated Structural Plates |
NAICS | n/a |
SIC | 3479 - Metal Coating And Allied Services |
Sales | $10,000,000-$50,000,000 |
# of Employees | 56 |
Plant Area (Sq.Ft.) | 160,000 |
Annual Production | 22,000 Tons |
Production Hrs. Annual | 2,040 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $64,687 | 2,287,808 | kWh | $0.03 |
Electricity Demand | $33,804 | 7,575 | kW-months/year | $4.46 |
Electricity Fees | $10,791 | - | $ | - |
Natural Gas | $147,046 | 38,658 | MMBtu | $3.80 |
TOTAL ENERGY COSTS | $300,592 | |||
RECOMMENDED SAVINGS* | $80,842 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $75,098 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (haz) | Electricity Usage | Electricity Demand | Other Liquid (haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $5,744 Cost: $16,350 |
$4,048 | 143,025 | $1,696 | 380 | - | - |
$4,048 143,025 kWh |
$1,696 380 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.5145 RECOVER AND REUSE SPENT ACID BATHS |
Savings: $67,100 Cost: $32,500 |
- | - | - | - | $67,100 | 124,000 |
- - kWh |
- - kW-months/year |
$67,100 124,000 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.8133 CONVERT TO AQUEOUS CLEANING |
Savings: $3,798 Cost: $4,160 |
- | - | - | - | $3,798 | 1,728 |
- - kWh |
- - kW-months/year |
$3,798 1,728 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $4,200 Cost: $4,200 |
- | - | - | - | $4,200 | 199 |
- - kWh |
- - kW-months/year |
$4,200 199 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $80,842 Cost: $57,210 |
$4,048 | 143,025 | $1,696 | 380 | $75,098 | 125,927 | $4,048 143,025 kWh |
$1,696 380 kW-months/year |
$75,098 125,927 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $75,098 Cost: $40,860 |
- | - | - | - | $75,098 | 125,927 | - - kWh |
- - kW-months/year |
$75,098 125,927 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (haz) | Electricity Usage | Electricity Demand | Other Liquid (haz) |