IAC Center | University of Louisville |
---|---|
Assessment Year | 1998 |
Principal Product | Injection Molded Plastic, Plastic Appliance Parts |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 250 |
Plant Area (Sq.Ft.) | 220,000 |
Annual Production | 5,000,000 Pieces |
Production Hrs. Annual | 8,592 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $300,982 | 12,145,663 | kWh | $0.02 |
Electricity Demand | $244,027 | 23,200 | kW-months/year | $10.52 |
Electricity Fees | $1,722 | - | $ | - |
Natural Gas | $42,362 | 8,366 | MMBtu | $5.06 |
TOTAL ENERGY COSTS | $602,446 | |||
RECOMMENDED SAVINGS* | $228,379 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $99,499 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Product | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $67,516 Cost: - |
- | - | $67,516 | - | - | - | - | - |
- - kWh |
$67,516 - kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,803 Cost: - |
$2,128 | 97,011 | $1,675 | 160 | - | - | - | - |
$2,128 97,011 kWh |
$1,675 160 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $28,180 Cost: - |
- | - | - | - | $28,180 | 200,000 | - | - |
- - kWh |
- - kW-months/year |
$28,180 200,000 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.4460 AUTOMATE FINISHING PROCESS |
Savings: $128,880 Cost: - |
- | - | - | - | - | - | $128,880 | - |
- - kWh |
- - kW-months/year |
- - lb |
$128,880 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $228,379 Cost: - |
$2,128 | 97,011 | $69,191 | 160 | $28,180 | 200,000 | $128,880 | - | $2,128 97,011 kWh |
$69,191 160 kW-months/year |
$28,180 200,000 lb |
$128,880 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $99,499 Cost: - |
$2,128 | 97,011 | $69,191 | 160 | $28,180 | 200,000 | - | - | $2,128 97,011 kWh |
$69,191 160 kW-months/year |
$28,180 200,000 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Product | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Product |