IAC Center | University of Louisville |
---|---|
Assessment Year | 2022 |
Principal Product | Pharmaceutical Distribution |
NAICS | 424210 - Drugs and Druggists' Sundries Merchant Wholesalers |
SIC | 5122 - Drugs, Proprietaries, And Sundries |
Sales | <$500,000 |
# of Employees | 30 |
Plant Area (Sq.Ft.) | 168,000 |
Annual Production | 12,200,000 Units |
Production Hrs. Annual | 8,568 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $89,289 | 1,876,441 | kWh | $0.05 |
Electricity Demand | $184,073 | 7,138 | kW-months/year | $25.79 |
Electricity Fees | $36,125 | - | $ | - |
Natural Gas | $86,447 | 7,791 | MMBtu | $11.10 |
TOTAL ENERGY COSTS | $395,934 | |||
RECOMMENDED SAVINGS* | $186,063 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,172 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,172 Cost: $939 |
$370 | 7,779 | $802 | 31 | - | - | - | - |
$370 7,779 kWh |
$802 31 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $8,205 Cost: - |
$2,660 | 55,385 | $5,545 | 213 | - | - | - | - |
$2,660 55,385 kWh |
$5,545 213 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,134 Cost: $521 |
$2,134 | 44,462 | - | - | - | - | - | - |
$2,134 44,462 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $6,981 Cost: - |
$6,981 | 145,444 | - | - | - | - | - | - |
$6,981 145,444 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $7,332 Cost: $3,015 |
- | - | - | - | $7,332 | - | - | - |
- - kWh |
- - kW-months/year |
$7,332 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.9112 USE SOLAR HEAT TO HEAT WATER |
Savings: $42,764 Cost: $150,000 |
- | - | - | - | - | - | $42,764 | 3,924 |
- - kWh |
- - kW-months/year |
- - $ |
$42,764 3,924 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $11,272 Cost: $137,883 |
$5,283 | 110,069 | $5,989 | 233 | - | - | - | - |
$5,283 110,069 kWh |
$5,989 233 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $106,203 Cost: $818,801 |
$51,413 | 1,071,114 | $54,790 | 2,124 | - | - | - | - |
$51,413 1,071,114 kWh |
$54,790 2,124 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $186,063 Cost: $1,111,159 |
$68,841 | 1,434,253 | $67,126 | 2,601 | $7,332 | - | $42,764 | 3,924 | $68,841 1,434,253 kWh |
$67,126 2,601 kW-months/year |
$7,332 - $ |
$42,764 3,924 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,172 Cost: $939 |
$370 | 7,779 | $802 | 31 | - | - | - | - | $370 7,779 kWh |
$802 31 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |