Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisville |
---|---|
Assessment Year | 2023 |
Principal Product | Printing Ink |
NAICS | 325910 - Printing Ink Manufacturing |
SIC | 2893 - Printing Ink |
Sales | $100,000,000-$500,000,000 |
# of Employees | 72 |
Plant Area (Sq.Ft.) | 350,000 |
Annual Production | 140,526,270 Pounds |
Production Hrs. Annual | 7,280 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $624,478 | 11,433,139 | kWh | $0.05 |
Electricity Demand | $157,386 | 24,304 | kW-months/year | $6.48 |
Electricity Fees | $416,751 | - | $ | - |
Natural Gas | $347,286 | 50,800 | MMBtu | $6.84 |
TOTAL ENERGY COSTS | $1,545,901 | |||
RECOMMENDED SAVINGS* | $135,369 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $20,753 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,819 Cost: $13,218 |
$8,829 | 161,643 | $1,990 | 307 | - | - |
$8,829 161,643 kWh |
$1,990 307 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,078 Cost: $2,711 |
$2,078 | 37,773 | - | - | - | - |
$2,078 37,773 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE |
Savings: $4,286 Cost: $1,600 |
$4,286 | 78,467 | - | - | - | - |
$4,286 78,467 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,735 Cost: - |
$1,458 | 26,687 | $277 | 43 | - | - |
$1,458 26,687 kWh |
$277 43 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,230 Cost: $1,980 |
$2,230 | 40,536 | - | - | - | - |
$2,230 40,536 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $22,148 Cost: $29,250 |
- | - | - | - | $22,148 | 3,240 |
- - kWh |
- - kW-months/year |
$22,148 3,240 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $3,418 Cost: $1,000 |
- | - | - | - | $3,418 | 500 |
- - kWh |
- - kW-months/year |
$3,418 500 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,714 Cost: $9,750 |
$4,714 | 86,303 | - | - | - | - |
$4,714 86,303 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $83,941 Cost: $859,381 |
$69,492 | 1,263,492 | $14,449 | 2,230 | - | - |
$69,492 1,263,492 kWh |
$14,449 2,230 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $135,369 Cost: $918,890 |
$93,087 | 1,694,901 | $16,716 | 2,580 | $25,566 | 3,740 | $93,087 1,694,901 kWh |
$16,716 2,580 kW-months/year |
$25,566 3,740 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $20,753 Cost: $17,798 |
$15,345 | 280,646 | $1,990 | 307 | $3,418 | 500 | $15,345 280,646 kWh |
$1,990 307 kW-months/year |
$3,418 500 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |