Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisville |
---|---|
Assessment Year | 2023 |
Principal Product | Sensor and Systems for position measurements |
NAICS | 334513 - Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial |
SIC | 3625 - Relays And Industrial Controls |
Sales | $100,000,000-$500,000,000 |
# of Employees | 170 |
Plant Area (Sq.Ft.) | 104,600 |
Annual Production | 480,000 Pieces |
Production Hrs. Annual | 4,680 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $59,998 | 1,000,207 | kWh | $0.06 |
Electricity Demand | $25,685 | 2,762 | kW-months/year | $9.30 |
Electricity Fees | $38,411 | - | $ | - |
Natural Gas | $12,356 | 901 | MMBtu | $13.71 |
TOTAL ENERGY COSTS | $143,827 | |||
RECOMMENDED SAVINGS* | $41,032 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $15,041 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $5,925 Cost: - |
$4,746 | 79,105 | $1,179 | 127 |
$4,746 79,105 kWh |
$1,179 127 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $5,419 Cost: $15,000 |
$3,884 | 64,734 | $1,535 | 165 |
$3,884 64,734 kWh |
$1,535 165 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $450 Cost: - |
$450 | 7,492 | - | - |
$450 7,492 kWh |
- - kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,248 Cost: $1,620 |
$3,248 | 54,130 | - | - |
$3,248 54,130 kWh |
- - kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $167 Cost: $488 |
$167 | 2,776 | - | - |
$167 2,776 kWh |
- - kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $18,666 Cost: $224,516 |
$13,250 | 220,832 | $5,416 | 582 |
$13,250 220,832 kWh |
$5,416 582 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7424 SHADE WINDOWS FROM SUMMER SUN |
Savings: $7,159 Cost: $34,500 |
$3,588 | 59,800 | $3,571 | 384 |
$3,588 59,800 kWh |
$3,571 384 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $41,032 Cost: $276,124 |
$29,332 | 488,869 | $11,700 | 1,258 | $29,332 488,869 kWh |
$11,700 1,258 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $15,041 Cost: $16,620 |
$12,328 | 205,461 | $2,713 | 292 | $12,328 205,461 kWh |
$2,713 292 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||