Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisville
Assessment Year 2023
Principal Product Sensor and Systems for position measurements
NAICS 334513 - Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial
SIC 3625 - Relays And Industrial Controls
Sales $100,000,000-$500,000,000
# of Employees 170
Plant Area (Sq.Ft.) 104,600
Annual Production 480,000 Pieces
Production Hrs. Annual 4,680
Location (State) KY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $59,998 1,000,207 kWh $0.06
Electricity Demand $25,685 2,762 kW-months/year $9.30
Electricity Fees $38,411 - $ -
Natural Gas $12,356 901 MMBtu $13.71
TOTAL ENERGY COSTS $143,827
RECOMMENDED SAVINGS* $41,032 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $15,041
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP Savings:
$5,925
Cost:
-
$4,746 79,105 $1,179 127 $4,746
79,105
kWh
$1,179
127
kW-months/year
02: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$5,419
Cost:
$15,000
$3,884 64,734 $1,535 165 $3,884
64,734
kWh
$1,535
165
kW-months/year
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$450
Cost:
-
$450 7,492 - - $450
7,492
kWh
-
-
kW-months/year
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,248
Cost:
$1,620
$3,248 54,130 - - $3,248
54,130
kWh
-
-
kW-months/year
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$167
Cost:
$488
$167 2,776 - - $167
2,776
kWh
-
-
kW-months/year
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$18,666
Cost:
$224,516
$13,250 220,832 $5,416 582 $13,250
220,832
kWh
$5,416
582
kW-months/year
07: 2.7424 SHADE WINDOWS FROM SUMMER SUN Savings:
$7,159
Cost:
$34,500
$3,588 59,800 $3,571 384 $3,588
59,800
kWh
$3,571
384
kW-months/year
TOTAL RECOMMENDED Savings:
$41,032
Cost:
$276,124
$29,332 488,869 $11,700 1,258 $29,332
488,869
kWh
$11,700
1,258
kW-months/year
TOTAL IMPLEMENTED Savings:
$15,041
Cost:
$16,620
$12,328 205,461 $2,713 292 $12,328
205,461
kWh
$2,713
292
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand