Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisville
Assessment Year 2024
Principal Product Canned Foods
NAICS 311999 - All Other Miscellaneous Food Manufacturing
SIC 2032 - Canned Specialties
Sales $10,000,000-$50,000,000
# of Employees 200
Plant Area (Sq.Ft.) 267,000
Annual Production 33,000,000 Pieces
Production Hrs. Annual 5,000
Location (State) KY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $206,739 6,394,920 kWh $0.03
Electricity Demand $348,620 15,845 kW-months/year $22.00
Electricity Fees $39,864 - $ -
Natural Gas $301,553 66,552 MMBtu $4.53
TOTAL ENERGY COSTS $896,776
RECOMMENDED SAVINGS* $189,720 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Water Usage Electricity Usage Electricity Demand Electricity Fees Water Usage
$ kWh $ kW-months/year $ $ $ Tgal
01: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$21,720
Cost:
$14,950
- - - - $21,720 - - - -
-
kWh
-
-
kW-months/year
$21,720
-
$
-
-
Tgal
02: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$7,741
Cost:
$12,220
- - - - $7,741 - - - -
-
kWh
-
-
kW-months/year
$7,741
-
$
-
-
Tgal
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$17,721
Cost:
$15,563
$6,783 209,994 $10,938 497 - - - - $6,783
209,994
kWh
$10,938
497
kW-months/year
-
-
$
-
-
Tgal
04: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$112
Cost:
$406
$112 3,469 - - - - - - $112
3,469
kWh
-
-
kW-months/year
-
-
$
-
-
Tgal
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$20,826
Cost:
$10,980
$20,826 650,799 - - - - - - $20,826
650,799
kWh
-
-
kW-months/year
-
-
$
-
-
Tgal
06: 2.4235 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES Savings:
$4,470
Cost:
$1,120
$2,299 71,855 $2,171 96 - - - - $2,299
71,855
kWh
$2,171
96
kW-months/year
-
-
$
-
-
Tgal
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,544
Cost:
$12,225
$3,544 110,761 - - - - - - $3,544
110,761
kWh
-
-
kW-months/year
-
-
$
-
-
Tgal
08: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$78,236
Cost:
$775,946
$33,945 1,060,797 $44,291 2,014 - - - - $33,945
1,060,797
kWh
$44,291
2,014
kW-months/year
-
-
$
-
-
Tgal
09: 2.2692 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER Savings:
$35,350
Cost:
$159,350
$638 19,748 $23,636 1,080 - - $11,076 2,313 $638
19,748
kWh
$23,636
1,080
kW-months/year
-
-
$
$11,076
2,313
Tgal
TOTAL RECOMMENDED Savings:
$189,720
Cost:
$1,002,760
$68,147 2,127,423 $81,036 3,686 $29,461 - $11,076 2,313 $68,147
2,127,423
kWh
$81,036
3,686
kW-months/year
$29,461
-
$
$11,076
2,313
Tgal
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
-
-
Tgal
Savings
Cost
$ kWh $ kW-months/year $ $ $ Tgal
Electricity Usage Electricity Demand Electricity Fees Water Usage Electricity Usage Electricity Demand Electricity Fees Water Usage