Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisville |
---|---|
Assessment Year | 2024 |
Principal Product | Canned Foods |
NAICS | 311999 - All Other Miscellaneous Food Manufacturing |
SIC | 2032 - Canned Specialties |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 267,000 |
Annual Production | 33,000,000 Pieces |
Production Hrs. Annual | 5,000 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $206,739 | 6,394,920 | kWh | $0.03 |
Electricity Demand | $348,620 | 15,845 | kW-months/year | $22.00 |
Electricity Fees | $39,864 | - | $ | - |
Natural Gas | $301,553 | 66,552 | MMBtu | $4.53 |
TOTAL ENERGY COSTS | $896,776 | |||
RECOMMENDED SAVINGS* | $189,720 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Water Usage | Electricity Usage | Electricity Demand | Electricity Fees | Water Usage | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $21,720 Cost: $14,950 |
- | - | - | - | $21,720 | - | - | - |
- - kWh |
- - kW-months/year |
$21,720 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $7,741 Cost: $12,220 |
- | - | - | - | $7,741 | - | - | - |
- - kWh |
- - kW-months/year |
$7,741 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $17,721 Cost: $15,563 |
$6,783 | 209,994 | $10,938 | 497 | - | - | - | - |
$6,783 209,994 kWh |
$10,938 497 kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $112 Cost: $406 |
$112 | 3,469 | - | - | - | - | - | - |
$112 3,469 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $20,826 Cost: $10,980 |
$20,826 | 650,799 | - | - | - | - | - | - |
$20,826 650,799 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4235 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES |
Savings: $4,470 Cost: $1,120 |
$2,299 | 71,855 | $2,171 | 96 | - | - | - | - |
$2,299 71,855 kWh |
$2,171 96 kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,544 Cost: $12,225 |
$3,544 | 110,761 | - | - | - | - | - | - |
$3,544 110,761 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $78,236 Cost: $775,946 |
$33,945 | 1,060,797 | $44,291 | 2,014 | - | - | - | - |
$33,945 1,060,797 kWh |
$44,291 2,014 kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2692 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER |
Savings: $35,350 Cost: $159,350 |
$638 | 19,748 | $23,636 | 1,080 | - | - | $11,076 | 2,313 |
$638 19,748 kWh |
$23,636 1,080 kW-months/year |
- - $ |
$11,076 2,313 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $189,720 Cost: $1,002,760 |
$68,147 | 2,127,423 | $81,036 | 3,686 | $29,461 | - | $11,076 | 2,313 | $68,147 2,127,423 kWh |
$81,036 3,686 kW-months/year |
$29,461 - $ |
$11,076 2,313 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||