Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisville
Assessment Year 2024
Principal Product Fireproof Logs
NAICS 327390 - Other Concrete Product Manufacturing
SIC 3297 - Nonclay Refractories
Sales $10,000,000-$50,000,000
# of Employees 180
Plant Area (Sq.Ft.) 144,530
Annual Production 173,037 Units
Production Hrs. Annual 2,040
Location (State) KY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $68,881 1,737,740 kWh $0.04
Electricity Demand $221,566 11,274 kW-months/year $19.65
Electricity Fees $37,948 - $ -
Natural Gas $138,938 24,203 MMBtu $5.74
TOTAL ENERGY COSTS $467,333
RECOMMENDED SAVINGS* $123,802 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$76,606
Cost:
$698,579
$40,986 1,033,991 $35,620 1,812 - - $40,986
1,033,991
kWh
$35,620
1,812
kW-months/year
-
-
MMBtu
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$746
Cost:
$2,700
$160 4,035 - - $586 102 $160
4,035
kWh
-
-
kW-months/year
$586
102
MMBtu
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,717
Cost:
$1,995
$1,717 43,352 - - - - $1,717
43,352
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.1121 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING Savings:
$4,053
Cost:
$13,653
- - - - $4,053 706 -
-
kWh
-
-
kW-months/year
$4,053
706
MMBtu
05: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$5,372
Cost:
$5,000
- - $5,372 276 - - -
-
kWh
$5,372
276
kW-months/year
-
-
MMBtu
06: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$35,308
Cost:
$50,000
- - - - $35,308 6,151 -
-
kWh
-
-
kW-months/year
$35,308
6,151
MMBtu
TOTAL RECOMMENDED Savings:
$123,802
Cost:
$771,927
$42,863 1,081,378 $40,992 2,088 $39,947 6,959 $42,863
1,081,378
kWh
$40,992
2,088
kW-months/year
$39,947
6,959
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu