Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisville
Assessment Year 2024
Principal Product Nickel plated automotive parts
NAICS 332813 - Electroplating, Plating, Polishing, Anodizing, and Coloring
SIC 3479 - Metal Coating And Allied Services
Sales $1,000,000-$5,000,000
# of Employees 19
Plant Area (Sq.Ft.) 54,200
Annual Production 1,100,000 Pieces
Production Hrs. Annual 3,510
Location (State) KY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $108,507 1,846,300 kWh $0.06
Electricity Demand $28,120 6,435 kW-months/year $4.37
Electricity Fees $53,187 - $ -
Natural Gas $134,417 15,123 MMBtu $8.89
TOTAL ENERGY COSTS $324,231
RECOMMENDED SAVINGS* $36,932 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$30,391
Cost:
$318,570
$26,779 455,662 $3,612 827 - - $26,779
455,662
kWh
$3,612
827
kW-months/year
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,324
Cost:
$627
$1,034 17,592 $290 66 - - $1,034
17,592
kWh
$290
66
kW-months/year
-
-
MMBtu
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$5,217
Cost:
$13,000
- - - - $5,217 587 -
-
kWh
-
-
kW-months/year
$5,217
587
MMBtu
TOTAL RECOMMENDED Savings:
$36,932
Cost:
$332,197
$27,813 473,254 $3,902 893 $5,217 587 $27,813
473,254
kWh
$3,902
893
kW-months/year
$5,217
587
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas