IAC logo
IAC Assessment: UL2417
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UL2417
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisville
Assessment Year 2024
Principal Product Aluminum wire
NAICS 331313 - Alumina Refining and Primary Aluminum Production
SIC 3313 - Electrometallurgical Products
Sales $50,000,000-$100,000,000
# of Employees 46
Plant Area (Sq.Ft.) 150,000
Annual Production 10,000,000 Pounds
Production Hrs. Annual 6,240
Location (State) KY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $51,475 1,514,000 kWh $0.03
Electricity Demand $96,576 4,237 kW-months/year $22.79
Electricity Fees $14,335 - $ -
Natural Gas $119,833 18,565 MMBtu $6.45
TOTAL ENERGY COSTS $282,219
RECOMMENDED SAVINGS* $86,585 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Water Usage Electricity Usage Electricity Demand Natural Gas Water Usage
$ kWh $ kW-months/year $ MMBtu $ Tgal
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$55,561
Cost:
$524,124
$24,563 722,437 $30,998 1,356 - - - - $24,563
722,437
kWh
$30,998
1,356
kW-months/year
-
-
MMBtu
-
-
Tgal
02: 2.2692 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER Savings:
$12,753
Cost:
$43,234
$479 14,094 $1,530 67 - - $10,744 200 $479
14,094
kWh
$1,530
67
kW-months/year
-
-
MMBtu
$10,744
200
Tgal
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$12,850
Cost:
$39,000
- - - - $12,850 1,991 - - -
-
kWh
-
-
kW-months/year
$12,850
1,991
MMBtu
-
-
Tgal
04: 2.1121 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING Savings:
$2,595
Cost:
$5,797
- - - - $2,595 402 - - -
-
kWh
-
-
kW-months/year
$2,595
402
MMBtu
-
-
Tgal
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$463
Cost:
-
$463 13,622 - - - - - - $463
13,622
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,025
Cost:
$525
$1,025 30,161 - - - - - - $1,025
30,161
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
07: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP Savings:
$900
Cost:
-
$393 11,562 $507 22 - - - - $393
11,562
kWh
$507
22
kW-months/year
-
-
MMBtu
-
-
Tgal
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$438
Cost:
$941
$438 12,874 - - - - - - $438
12,874
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
TOTAL RECOMMENDED Savings:
$86,585
Cost:
$613,621
$27,361 804,750 $33,035 1,445 $15,445 2,393 $10,744 200 $27,361
804,750
kWh
$33,035
1,445
kW-months/year
$15,445
2,393
MMBtu
$10,744
200
Tgal
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ Tgal
Electricity Usage Electricity Demand Natural Gas Water Usage Electricity Usage Electricity Demand Natural Gas Water Usage