IAC logo
IAC Assessment: UM0129
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UM0129
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 1999
Principal Product Baked Graphite Seals
NAICS n/a
SIC 3624 - Carbon And Graphite Products
Sales $5,000,000-$10,000,000
# of Employees 100
Plant Area (Sq.Ft.) 60,000
Annual Production 0 Units
Production Hrs. Annual 8,760
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $143,865 4,288,394 kWh $0.03
Electricity Demand $77,713 9,060 kW-months/year $8.58
Electricity Fees $21,206 - $ -
Natural Gas $308,434 94,036 MMBtu $3.28
TOTAL ENERGY COSTS $551,218
RECOMMENDED SAVINGS* $191,367 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes One-time Revenue or Avoided Cost By-product Production Electricity Usage Electricity Demand Natural Gas Personnel Changes One-time Revenue or Avoided Cost By-product Production
$ kWh $ kW-months/year $ MMBtu $ $ $ $ $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$7,119
Cost:
$13,195
$5,470 140,973 $1,649 220 - - - - - - - - $5,470
140,973
kWh
$1,649
220
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$21,707
Cost:
$23,612
$10,990 313,892 - - - - $10,717 - - - - - $10,990
313,892
kWh
-
-
kW-months/year
-
-
MMBtu
$10,717
-
$
-
-
$
-
-
$
03: 2.1224 REPLACE BOILER Savings:
$78,528
Cost:
$13,800
- - - - $528 159 - - $78,000 - - - -
-
kWh
-
-
kW-months/year
$528
159
MMBtu
-
-
$
$78,000
-
$
-
-
$
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$24,159
Cost:
$17,000
- - - - $24,159 7,277 - - - - - - -
-
kWh
-
-
kW-months/year
$24,159
7,277
MMBtu
-
-
$
-
-
$
-
-
$
05: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS Savings:
$56,391
Cost:
$122,400
- - - - - - - - - - $56,391 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
$56,391
-
$
06: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS Savings:
$3,463
Cost:
$19,860
- - - - - - $3,463 - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$3,463
-
$
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$191,367
Cost:
$209,867
$16,460 454,865 $1,649 220 $24,687 7,436 $14,180 - $78,000 - $56,391 - $16,460
454,865
kWh
$1,649
220
kW-months/year
$24,687
7,436
MMBtu
$14,180
-
$
$78,000
-
$
$56,391
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $ $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes One-time Revenue or Avoided Cost By-product Production Electricity Usage Electricity Demand Natural Gas Personnel Changes One-time Revenue or Avoided Cost By-product Production