Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 2000 |
Principal Product | Sealants and Adhesives |
NAICS | n/a |
SIC | 2891 - Adhesives And Sealants |
Sales | $50,000,000-$100,000,000 |
# of Employees | 275 |
Plant Area (Sq.Ft.) | 200,000 |
Annual Production | 58,000,000 Pounds |
Production Hrs. Annual | 6,100 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $391,451 | 10,927,609 | kWh | $0.04 |
Electricity Demand | $228,352 | 25,116 | kW-months/year | $9.09 |
Electricity Fees | $16,765 | - | $ | - |
Natural Gas | $114,132 | 37,905 | MMBtu | $3.01 |
TOTAL ENERGY COSTS | $750,700 | |||
RECOMMENDED SAVINGS* | $69,063 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $67,463 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,149 Cost: $200 |
$817 | 22,567 | $332 | 44 | - | - | - | - | - | - |
$817 22,567 kWh |
$332 44 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $582 Cost: $50 |
$413 | 11,430 | $169 | 22 | - | - | - | - | - | - |
$413 11,430 kWh |
$169 22 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3137 USE POWER DURING OFF-PEAK PERIODS |
Savings: $55,632 Cost: $22,000 |
- | - | $55,632 | 7,200 | - | - | - | - | - | - |
- - kWh |
$55,632 7,200 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7229 AIR CONDITION ONLY SPACE NECESSARY |
Savings: $2,800 Cost: $220 |
- | - | - | - | $2,800 | 920 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,800 920 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $7,300 Cost: $500 |
- | - | - | - | - | - | $7,300 | 16,800 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$7,300 16,800 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $1,600 Cost: $300 |
- | - | - | - | - | - | - | - | $1,600 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$1,600 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $69,063 Cost: $23,270 |
$1,230 | 33,997 | $56,133 | 7,266 | $2,800 | 920 | $7,300 | 16,800 | $1,600 | - | $1,230 33,997 kWh |
$56,133 7,266 kW-months/year |
$2,800 920 MMBtu |
$7,300 16,800 lb |
$1,600 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $67,463 Cost: $22,970 |
$1,230 | 33,997 | $56,133 | 7,266 | $2,800 | 920 | $7,300 | 16,800 | - | - | $1,230 33,997 kWh |
$56,133 7,266 kW-months/year |
$2,800 920 MMBtu |
$7,300 16,800 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Raw Material |