Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 2001 |
Principal Product | Automotive Specialty Products |
NAICS | n/a |
SIC | 3469 - Metal Stampings, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 95 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 8,736 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $72,662 | 2,162,075 | kWh | $0.03 |
Electricity Demand | $84,713 | 4,596 | kW-months/year | $18.43 |
Electricity Fees | $34,983 | - | $ | - |
Natural Gas | $37,391 | 9,693 | MMBtu | $3.86 |
TOTAL ENERGY COSTS | $229,749 | |||
RECOMMENDED SAVINGS* | $62,420 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $56,771 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $27,600 Cost: $7,600 |
- | - | - | - | $27,600 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$27,600 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,649 Cost: $10,474 |
$3,388 | 92,614 | $2,261 | 138 | - | - | - | - | - | - |
$3,388 92,614 kWh |
$2,261 138 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,341 Cost: $800 |
$1,341 | 40,152 | - | - | - | - | - | - | - | - |
$1,341 40,152 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $6,130 Cost: $3,850 |
- | - | - | - | - | - | $6,130 | 1,672 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$6,130 1,672 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2531 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR |
Savings: $700 Cost: $700 |
- | - | - | - | - | - | $700 | 184 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$700 184 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $21,000 Cost: $20,000 |
- | - | - | - | - | - | - | - | $21,000 | 1,600,000 |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$21,000 1,600,000 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $62,420 Cost: $43,424 |
$4,729 | 132,766 | $2,261 | 138 | $27,600 | - | $6,830 | 1,856 | $21,000 | 1,600,000 | $4,729 132,766 kWh |
$2,261 138 kW-months/year |
$27,600 - $ |
$6,830 1,856 MMBtu |
$21,000 1,600,000 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $56,771 Cost: $32,950 |
$1,341 | 40,152 | - | - | $27,600 | - | $6,830 | 1,856 | $21,000 | 1,600,000 | $1,341 40,152 kWh |
- - kW-months/year |
$27,600 - $ |
$6,830 1,856 MMBtu |
$21,000 1,600,000 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) |