Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 2003
Principal Product Coating Automotive Parts
NAICS 332812 - Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers
SIC 3479 - Metal Coating And Allied Services
Sales $10,000,000-$50,000,000
# of Employees 35
Plant Area (Sq.Ft.) 486,530
Annual Production 0 Units
Production Hrs. Annual 2,280
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $131,042 1,902,511 kWh $0.07
Electricity Demand $82,877 6,588 kW-months/year $12.58
Electricity Fees $(-6,041) - $ -
Natural Gas $17,512 3,514 MMBtu $4.98
TOTAL ENERGY COSTS $225,390
RECOMMENDED SAVINGS* $25,354 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$18,914
Cost:
$100,000
$19,568 284,000 $5,396 429 $(-6,050) (-1,210) $19,568
284,000
kWh
$5,396
429
kW-months/year
$(-6,050)
(-1,210)
MMBtu
02: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$2,030
Cost:
$5,280
- - - - $2,030 324 -
-
kWh
-
-
kW-months/year
$2,030
324
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,440
Cost:
$6,423
$1,032 14,986 $1,408 108 - - $1,032
14,986
kWh
$1,408
108
kW-months/year
-
-
MMBtu
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,970
Cost:
$300
$1,272 18,464 $698 56 - - $1,272
18,464
kWh
$698
56
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$25,354
Cost:
$112,003
$21,872 317,450 $7,502 593 $(-4,020) (-886) $21,872
317,450
kWh
$7,502
593
kW-months/year
$(-4,020)
(-886)
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas