Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 2003 |
Principal Product | Corrugated Containers |
NAICS | 322211 - Corrugated and Solid Fiber Box Manufacturing |
SIC | 2653 - Corrugated And Solid Fiber Boxes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 160,000 |
Annual Production | 44,000 Tons |
Production Hrs. Annual | 1,980 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $141,688 | 5,728,450 | kWh | $0.02 |
Electricity Demand | $243,488 | 13,375 | kW-months/year | $18.20 |
Electricity Fees | $3,721 | - | $ | - |
Natural Gas | $489,563 | 56,660 | MMBtu | $8.64 |
TOTAL ENERGY COSTS | $913,540 | |||
RECOMMENDED SAVINGS* | $120,305 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $86,885 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $28,120 Cost: $1,000 |
- | - | - | - | $28,120 | 3,255 | - | - |
- - kWh |
- - kW-months/year |
$28,120 3,255 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $17,060 Cost: $5,000 |
$15,150 | 612,695 | $1,910 | 105 | - | - | - | - |
$15,150 612,695 kWh |
$1,910 105 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $16,440 Cost: $2,500 |
- | - | - | - | $17,490 | 2,025 | $(-1,050) | - |
- - kWh |
- - kW-months/year |
$17,490 2,025 MMBtu |
$(-1,050) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $14,980 Cost: $9,450 |
$(-320) | (-12,960) | $(-945) | (-52) | $16,245 | 1,880 | - | - |
$(-320) (-12,960) kWh |
$(-945) (-52) kW-months/year |
$16,245 1,880 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $14,410 Cost: $5,000 |
$7,155 | 289,340 | $7,255 | 397 | - | - | - | - |
$7,155 289,340 kWh |
$7,255 397 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $9,445 Cost: $2,700 |
- | - | - | - | $9,445 | 1,093 | - | - |
- - kWh |
- - kW-months/year |
$9,445 1,093 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $7,305 Cost: $500 |
$7,305 | 295,343 | - | - | - | - | - | - |
$7,305 295,343 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $6,425 Cost: $414 |
- | - | - | - | $6,425 | 743 | - | - |
- - kWh |
- - kW-months/year |
$6,425 743 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4324 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT |
Savings: $3,550 Cost: $1,100 |
$1,130 | 45,865 | $2,420 | 133 | - | - | - | - |
$1,130 45,865 kWh |
$2,420 133 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,570 Cost: $4,301 |
$1,730 | 70,052 | $840 | 46 | - | - | - | - |
$1,730 70,052 kWh |
$840 46 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $120,305 Cost: $31,965 |
$32,150 | 1,300,335 | $11,480 | 629 | $77,725 | 8,996 | $(-1,050) | - | $32,150 1,300,335 kWh |
$11,480 629 kW-months/year |
$77,725 8,996 MMBtu |
$(-1,050) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $86,885 Cost: $15,100 |
$30,740 | 1,243,243 | $11,585 | 635 | $45,610 | 5,280 | $(-1,050) | - | $30,740 1,243,243 kWh |
$11,585 635 kW-months/year |
$45,610 5,280 MMBtu |
$(-1,050) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |