Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 2005 |
Principal Product | Coated Paper Board |
NAICS | 322130 - Paperboard Mills |
SIC | 2631 - Paperboard Mills |
Sales | $50,000,000-$100,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 210,000 |
Annual Production | 125,000 Tons |
Production Hrs. Annual | 8,400 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,724,968 | 55,633,064 | kWh | $0.03 |
Electricity Demand | $1,000,000 | 92,297 | kW-months/year | $10.83 |
Electricity Fees | $1,364 | - | $ | - |
Natural Gas | $2,000,000 | 1,100,220 | MMBtu | $1.82 |
TOTAL ENERGY COSTS | $4,726,332 | |||
RECOMMENDED SAVINGS* | $874,158 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $210,672 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3192 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS |
Savings: $206,100 Cost: $96,000 |
- | - | $206,100 | 18,000 | - | - |
- - kWh |
$206,100 18,000 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $4,572 Cost: $2,500 |
$335 | 10,800 | $4,237 | 370 | - | - |
$335 10,800 kWh |
$4,237 370 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $663,486 Cost: $7,500,000 |
$1,562,904 | 50,400,000 | $824,400 | 72,000 | $(-1,723,818) | (-287,303) |
$1,562,904 50,400,000 kWh |
$824,400 72,000 kW-months/year |
$(-1,723,818) (-287,303) MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $874,158 Cost: $7,598,500 |
$1,563,239 | 50,410,800 | $1,034,737 | 90,370 | $(-1,723,818) | (-287,303) | $1,563,239 50,410,800 kWh |
$1,034,737 90,370 kW-months/year |
$(-1,723,818) (-287,303) MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $210,672 Cost: $98,500 |
$335 | 10,800 | $210,337 | 18,370 | - | - | $335 10,800 kWh |
$210,337 18,370 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |