IAC logo
IAC Assessment: UM0319
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UM0319
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 2007
Principal Product Carbonated and Non-Carbonated Soft Drinks
NAICS 312111 - Soft Drink Manufacturing
SIC 2086 - Bottled And Canned Soft Drinks
Sales $50,000,000-$100,000,000
# of Employees 335
Plant Area (Sq.Ft.) 212,578
Annual Production 36,000,000 Units
Production Hrs. Annual 7,488
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $479,160 8,910,215 kWh $0.05
Electricity Demand $262,823 21,583 kW-months/year $12.18
Electricity Fees $54,745 - $ -
Natural Gas $607,903 46,625 MMBtu $13.04
TOTAL ENERGY COSTS $1,404,631
RECOMMENDED SAVINGS* $205,065 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $73,559
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Water Consumption Electricity Usage Electricity Demand Natural Gas Water Consumption
$ kWh $ kW-months/year $ MMBtu $ Tgal
01: 3.4115 RECOVER AND REUSE COOLING WATER Savings:
$56,454
Cost:
-
- - - - $22,481 1,724 $33,973 - -
-
kWh
-
-
kW-months/year
$22,481
1,724
MMBtu
$33,973
-
Tgal
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$31,763
Cost:
-
$135,309 2,515,968 $49,110 4,032 $(-186,629) (-14,312) $33,973 - $135,309
2,515,968
kWh
$49,110
4,032
kW-months/year
$(-186,629)
(-14,312)
MMBtu
$33,973
-
Tgal
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$28,235
Cost:
$20,000
$20,720 385,282 $7,515 617 - - - - $20,720
385,282
kWh
$7,515
617
kW-months/year
-
-
MMBtu
-
-
Tgal
04: 3.4157 REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING Savings:
$33,973
Cost:
$300,000
- - - - - - $33,973 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$33,973
-
Tgal
05: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$20,590
Cost:
-
$(-716) (-13,319) $(-223) (-18) $21,529 1,651 - - $(-716)
(-13,319)
kWh
$(-223)
(-18)
kW-months/year
$21,529
1,651
MMBtu
-
-
Tgal
06: 3.4151 MINIMIZE WATER USAGE Savings:
$15,684
Cost:
-
- - - - - - $15,684 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$15,684
-
Tgal
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$9,128
Cost:
$2,200
- - - - $9,128 700 - - -
-
kWh
-
-
kW-months/year
$9,128
700
MMBtu
-
-
Tgal
08: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$7,015
Cost:
-
- - - - $7,015 538 - - -
-
kWh
-
-
kW-months/year
$7,015
538
MMBtu
-
-
Tgal
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,223
Cost:
$86,000
$1,631 30,326 $592 49 - - - - $1,631
30,326
kWh
$592
49
kW-months/year
-
-
MMBtu
-
-
Tgal
TOTAL RECOMMENDED Savings:
$205,065
Cost:
$408,200
$156,944 2,918,257 $56,994 4,680 $(-126,476) (-9,699) $117,603 - $156,944
2,918,257
kWh
$56,994
4,680
kW-months/year
$(-126,476)
(-9,699)
MMBtu
$117,603
-
Tgal
TOTAL IMPLEMENTED Savings:
$73,559
Cost:
$408,200
$22,351 415,608 $8,107 666 $9,128 700 $33,973 - $22,351
415,608
kWh
$8,107
666
kW-months/year
$9,128
700
MMBtu
$33,973
-
Tgal
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ Tgal
Electricity Usage Electricity Demand Natural Gas Water Consumption Electricity Usage Electricity Demand Natural Gas Water Consumption