Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 2007 |
Principal Product | Carbide Pre-Form Cutting Tools |
NAICS | 333517 - Machine Tool Manufacturing |
SIC | 3545 - Machine Tool Accessories |
Sales | $10,000,000-$50,000,000 |
# of Employees | 108 |
Plant Area (Sq.Ft.) | 37,855 |
Annual Production | 50,500 Pieces |
Production Hrs. Annual | 6,120 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $185,295 | 3,529,691 | kWh | $0.05 |
Electricity Demand | $93,899 | 8,830 | kW-months/year | $10.63 |
Electricity Fees | $3,032 | - | $ | - |
Natural Gas | $20,488 | 16,103 | MMBtu | $1.27 |
TOTAL ENERGY COSTS | $302,714 | |||
RECOMMENDED SAVINGS* | $44,569 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,752 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Gaseous Waste | Electricity Usage | Electricity Demand | Natural Gas | Gaseous Waste | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $37,752 Cost: $38,000 |
- | - | - | - | - | - | $37,752 | 146,982 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$37,752 146,982 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,146 Cost: $12,000 |
$2,252 | 42,901 | $894 | 84 | - | - | - | - |
$2,252 42,901 kWh |
$894 84 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2425 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER |
Savings: $2,277 Cost: $4,600 |
- | - | - | - | $2,277 | 179 | - | - |
- - kWh |
- - kW-months/year |
$2,277 179 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $788 Cost: $500 |
$565 | 10,763 | $223 | 21 | - | - | - | - |
$565 10,763 kWh |
$223 21 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $606 Cost: - |
$434 | 8,262 | $172 | 16 | - | - | - | - |
$434 8,262 kWh |
$172 16 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $44,569 Cost: $55,100 |
$3,251 | 61,926 | $1,289 | 121 | $2,277 | 179 | $37,752 | 146,982 | $3,251 61,926 kWh |
$1,289 121 kW-months/year |
$2,277 179 MMBtu |
$37,752 146,982 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,752 Cost: $12,000 |
$2,686 | 51,163 | $1,066 | 100 | - | - | - | - | $2,686 51,163 kWh |
$1,066 100 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Gaseous Waste | Electricity Usage | Electricity Demand | Natural Gas | Gaseous Waste |