Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 2009 |
Principal Product | Decorative Plating |
NAICS | 332813 - Electroplating, Plating, Polishing, Anodizing, and Coloring |
SIC | 3471 - Plating And Polishing |
Sales | $5,000,000-$10,000,000 |
# of Employees | 43 |
Plant Area (Sq.Ft.) | 56,000 |
Annual Production | 1 Units |
Production Hrs. Annual | 3,536 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $90,532 | 2,546,933 | kWh | $0.04 |
Electricity Demand | $37,449 | 86,864 | kW-months/year | $0.43 |
Natural Gas | $250,988 | 29,961 | MMBtu | $8.38 |
TOTAL ENERGY COSTS | $378,969 | |||
RECOMMENDED SAVINGS* | $87,492 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $78,732 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2522 ISOLATE HOT OR COLD EQUIPMENT |
Savings: $21,998 Cost: $720 |
- | - | - | - | $21,998 | 2,625 |
- - kWh |
- - kW-months/year |
$21,998 2,625 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,988 Cost: $23,603 |
$5,376 | 107,744 | $1,612 | 126 | - | - |
$5,376 107,744 kWh |
$1,612 126 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $4,994 Cost: $10,960 |
- | - | - | - | $4,994 | 590 |
- - kWh |
- - kW-months/year |
$4,994 590 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $3,766 Cost: $1,200 |
- | - | - | - | $3,766 | 490 |
- - kWh |
- - kW-months/year |
$3,766 490 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $69 Cost: $62 |
- | - | - | - | $69 | 8 |
- - kWh |
- - kW-months/year |
$69 8 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $44,552 Cost: $36,000 |
$32,312 | 646,630 | $12,240 | 973 | - | - |
$32,312 646,630 kWh |
$12,240 973 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $5,125 Cost: $11,770 |
- | - | - | - | $5,125 | 612 |
- - kWh |
- - kW-months/year |
$5,125 612 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $87,492 Cost: $84,315 |
$37,688 | 754,374 | $13,852 | 1,099 | $35,952 | 4,325 | $37,688 754,374 kWh |
$13,852 1,099 kW-months/year |
$35,952 4,325 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $78,732 Cost: $72,155 |
$37,688 | 754,374 | $13,852 | 1,099 | $27,192 | 3,245 | $37,688 754,374 kWh |
$13,852 1,099 kW-months/year |
$27,192 3,245 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |