IAC logo
IAC Assessment: UM0361
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 2010
Principal Product Library Furniture
NAICS 337211 - Wood Office Furniture Manufacturing
SIC 2531 - Public Building & Related Furniture
Sales $10,000,000-$50,000,000
# of Employees 126
Plant Area (Sq.Ft.) 139,000
Annual Production 172,388 Pieces
Production Hrs. Annual 2,210
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $128,070 2,447,375 kWh $0.05
Electricity Demand $85,221 9,383 kW-months/year $9.08
Natural Gas $141,259 11,559 MMBtu $12.22
TOTAL ENERGY COSTS $354,550
RECOMMENDED SAVINGS* $123,379 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $31,121
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 3.6123 BURN WOOD BY-PRODUCTS FOR HEAT Savings:
$79,685
Cost:
$67,199
- - - - $79,685 5,202 -
-
kWh
-
-
kW-months/year
$79,685
5,202
MMBtu
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$9,763
Cost:
$100
- - - - $9,763 799 -
-
kWh
-
-
kW-months/year
$9,763
799
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$21,000
Cost:
$31,000
$10,816 206 $10,184 96 - - $10,816
206
kWh
$10,184
96
kW-months/year
-
-
MMBtu
04: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$3,484
Cost:
$1,200
- - - - $3,484 285 -
-
kWh
-
-
kW-months/year
$3,484
285
MMBtu
05: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$2,810
Cost:
$5,718
- - - - $2,810 230 -
-
kWh
-
-
kW-months/year
$2,810
230
MMBtu
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$2,522
Cost:
$600
- - - - $2,522 207 -
-
kWh
-
-
kW-months/year
$2,522
207
MMBtu
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,227
Cost:
$650
$1,147 21,921 $1,080 119 - - $1,147
21,921
kWh
$1,080
119
kW-months/year
-
-
MMBtu
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,137
Cost:
$5,520
$1,137 21,720 - - - - $1,137
21,720
kWh
-
-
kW-months/year
-
-
MMBtu
09: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$396
Cost:
$400
- - - - $396 32 -
-
kWh
-
-
kW-months/year
$396
32
MMBtu
10: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$355
Cost:
$750
$182 3,484 $173 19 - - $182
3,484
kWh
$173
19
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$123,379
Cost:
$113,137
$13,282 47,331 $11,437 234 $98,660 6,755 $13,282
47,331
kWh
$11,437
234
kW-months/year
$98,660
6,755
MMBtu
TOTAL IMPLEMENTED Savings:
$31,121
Cost:
$40,120
$13,282 47,331 $11,437 234 $6,402 524 $13,282
47,331
kWh
$11,437
234
kW-months/year
$6,402
524
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas