Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 2010 |
Principal Product | Coatings |
NAICS | 332812 - Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers |
SIC | 3479 - Metal Coating And Allied Services |
Sales | $5,000,000-$10,000,000 |
# of Employees | 119 |
Plant Area (Sq.Ft.) | 78,000 |
Annual Production | 1 Units |
Production Hrs. Annual | 6,120 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $130,939 | 2,692,240 | kWh | $0.05 |
Electricity Demand | $133,032 | 8,285 | kW-months/year | $16.06 |
Natural Gas | $252,284 | 33,386 | MMBtu | $7.56 |
TOTAL ENERGY COSTS | $516,255 | |||
RECOMMENDED SAVINGS* | $88,294 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $52,928 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $24,368 Cost: $36,732 |
$14,796 | 304,195 | $9,572 | 596 | - | - | - | - |
$14,796 304,195 kWh |
$9,572 596 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $7,625 Cost: $250 |
$7,625 | 156,771 | - | - | - | - | - | - |
$7,625 156,771 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $4,381 Cost: $9,416 |
$4,381 | 90,072 | - | - | - | - | - | - |
$4,381 90,072 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,012 Cost: $6,547 |
$1,540 | 31,662 | $2,472 | 154 | - | - | - | - |
$1,540 31,662 kWh |
$2,472 154 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,793 Cost: $200 |
$3,793 | 77,977 | - | - | - | - | - | - |
$3,793 77,977 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,126 Cost: $2,000 |
$1,986 | 40,825 | $1,140 | 71 | - | - | - | - |
$1,986 40,825 kWh |
$1,140 71 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,850 Cost: $2,850 |
- | - | - | - | $2,850 | - | - | - |
- - kWh |
- - kW-months/year |
$2,850 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $248 Cost: $10 |
$248 | 5,100 | - | - | - | - | - | - |
$248 5,100 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $1,943 Cost: $2,800 |
- | - | - | - | - | - | $1,943 | 257 |
- - kWh |
- - kW-months/year |
- - $ |
$1,943 257 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $582 Cost: $6,500 |
- | - | - | - | - | - | $582 | 77 |
- - kWh |
- - kW-months/year |
- - $ |
$582 77 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.2447 HEAT WATER WITH EXHAUST HEAT |
Savings: $35,366 Cost: $24,762 |
- | - | - | - | - | - | $35,366 | 4,368 |
- - kWh |
- - kW-months/year |
- - $ |
$35,366 4,368 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $88,294 Cost: $92,067 |
$34,369 | 706,602 | $13,184 | 821 | $2,850 | - | $37,891 | 4,702 | $34,369 706,602 kWh |
$13,184 821 kW-months/year |
$2,850 - $ |
$37,891 4,702 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $52,928 Cost: $67,305 |
$34,369 | 706,602 | $13,184 | 821 | $2,850 | - | $2,525 | 334 | $34,369 706,602 kWh |
$13,184 821 kW-months/year |
$2,850 - $ |
$2,525 334 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |