Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 2012
Principal Product auto components
NAICS 336360 - Motor Vehicle Seating and Interior Trim Manufacturing
SIC 3499 - Fabricated Metal Products, Nec
Sales $50,000,000-$100,000,000
# of Employees 270
Plant Area (Sq.Ft.) 203,840
Annual Production 42,500,000 Pieces
Production Hrs. Annual 4,375
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $235,858 6,197,000 kWh $0.04
Electricity Demand $142,689 11,026 kW-months/year $12.94
Natural Gas $33,078 3,783 MMBtu $8.74
TOTAL ENERGY COSTS $411,625
RECOMMENDED SAVINGS* $72,984 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$38,282
Cost:
$47,885
$18,610 474,767 $19,672 1,341 - - $18,610
474,767
kWh
$19,672
1,341
kW-months/year
-
-
MMBtu
02: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$15,755
Cost:
$17,500
$6,790 173,214 $8,965 611 - - $6,790
173,214
kWh
$8,965
611
kW-months/year
-
-
MMBtu
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$5,437
Cost:
$4,000
$5,437 138,692 - - - - $5,437
138,692
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$4,410
Cost:
$200
$4,410 112,489 - - - - $4,410
112,489
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$3,287
Cost:
$5,040
$3,287 83,862 - - - - $3,287
83,862
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$706
Cost:
$10
$706 18,000 - - - - $706
18,000
kWh
-
-
kW-months/year
-
-
MMBtu
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$3,660
Cost:
$4,000
- - - - $3,660 344 -
-
kWh
-
-
kW-months/year
$3,660
344
MMBtu
08: 2.7313 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING Savings:
$1,447
Cost:
$4,000
- - - - $1,447 136 -
-
kWh
-
-
kW-months/year
$1,447
136
MMBtu
TOTAL RECOMMENDED Savings:
$72,984
Cost:
$82,635
$39,240 1,001,024 $28,637 1,952 $5,107 480 $39,240
1,001,024
kWh
$28,637
1,952
kW-months/year
$5,107
480
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas