Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 2012
Principal Product steel coils
NAICS 336370 - Motor Vehicle Metal Stamping
SIC 3465 - Automotive Stampings
Sales $50,000,000-$100,000,000
# of Employees 107
Plant Area (Sq.Ft.) 200,000
Annual Production 40,000 Tons
Production Hrs. Annual 6,240
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $240,365 3,435,825 kWh $0.07
Electricity Demand $112,764 9,524 kW-months/year $11.84
Natural Gas $42,033 5,043 MMBtu $8.33
TOTAL ENERGY COSTS $395,162
RECOMMENDED SAVINGS* $30,446 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $15,433
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas Electricity Usage Electricity Demand Electricity Fees Natural Gas
$ kWh $ kW-months/year $ $ $ MMBtu
01: 2.4324 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT Savings:
$13,566
Cost:
$16,700
$14,241 203,445 $(-675) (-57) - - - - $14,241
203,445
kWh
$(-675)
(-57)
kW-months/year
-
-
$
-
-
MMBtu
02: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$10,324
Cost:
$2,000
- - - - $10,324 - - - -
-
kWh
-
-
kW-months/year
$10,324
-
$
-
-
MMBtu
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$2,021
Cost:
$1,500
$2,021 28,875 - - - - - - $2,021
28,875
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,447
Cost:
$200
$1,447 20,685 - - - - - - $1,447
20,685
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
05: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$595
Cost:
$100
$595 8,500 - - - - - - $595
8,500
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
06: 2.7291 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS Savings:
$1,364
Cost:
-
- - - - - - $1,364 168 -
-
kWh
-
-
kW-months/year
-
-
$
$1,364
168
MMBtu
07: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$1,129
Cost:
$1,000
- - - - - - $1,129 139 -
-
kWh
-
-
kW-months/year
-
-
$
$1,129
139
MMBtu
TOTAL RECOMMENDED Savings:
$30,446
Cost:
$21,500
$18,304 261,505 $(-675) (-57) $10,324 - $2,493 307 $18,304
261,505
kWh
$(-675)
(-57)
kW-months/year
$10,324
-
$
$2,493
307
MMBtu
TOTAL IMPLEMENTED Savings:
$15,433
Cost:
$4,600
$2,616 37,375 - - $10,324 - $2,493 307 $2,616
37,375
kWh
-
-
kW-months/year
$10,324
-
$
$2,493
307
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu
Electricity Usage Electricity Demand Electricity Fees Natural Gas Electricity Usage Electricity Demand Electricity Fees Natural Gas