IAC Center | University of Michigan |
---|---|
Assessment Year | 2016 |
Principal Product | Die cast machines |
NAICS | 333517 - Machine Tool Manufacturing |
SIC | 3542 - Machine Tools, Metal Forming Types |
Sales | $90,000,000 |
# of Employees | 121 |
Plant Area (Sq.Ft.) | 70,000 |
Annual Production | 40 Pieces |
Production Hrs. Annual | 3,120 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $123,581 | 2,095,200 | kWh | $0.06 |
Electricity Demand | $46,395 | 5,580 | kW-months/year | $8.31 |
Natural Gas | $58,337 | 8,284 | MMBtu | $7.04 |
TOTAL ENERGY COSTS | $228,313 | |||
RECOMMENDED SAVINGS* | $15,217 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,158 Cost: $5,250 |
$2,650 | 44,928 | $508 | 61 | - | - | - | - |
$2,650 44,928 kWh |
$508 61 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,640 Cost: $2,000 |
$1,064 | 18,049 | $576 | 69 | - | - | - | - |
$1,064 18,049 kWh |
$576 69 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $485 Cost: $1,029 |
$296 | 5,012 | $448 | 54 | $(-259) | (-37) | - | - |
$296 5,012 kWh |
$448 54 kW-months/year |
$(-259) (-37) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $8,573 Cost: - |
- | - | $9,573 | 1,152 | - | - | $(-1,000) | - |
- - kWh |
$9,573 1,152 kW-months/year |
- - MMBtu |
$(-1,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,361 Cost: $150 |
- | - | - | - | $1,361 | 193 | - | - |
- - kWh |
- - kW-months/year |
$1,361 193 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $15,217 Cost: $8,429 |
$4,010 | 67,989 | $11,105 | 1,337 | $1,102 | 157 | $(-1,000) | - | $4,010 67,989 kWh |
$11,105 1,337 kW-months/year |
$1,102 157 MMBtu |
$(-1,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |