IAC logo
IAC Assessment: UM0468
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UM0468
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 2016
Principal Product Anodize, Hardcoat, conversion coatings on aluminum
NAICS 332813 - Electroplating, Plating, Polishing, Anodizing, and Coloring
SIC 3471 - Plating And Polishing
Sales $10,000,000-$50,000,000
# of Employees 148
Plant Area (Sq.Ft.) 55,750
Annual Production 100,000,000 Pounds
Production Hrs. Annual 8,736
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $576,647 7,987,560 kWh $0.07
Natural Gas $32,206 31,475 MMBtu $1.02
TOTAL ENERGY COSTS $608,853
RECOMMENDED SAVINGS* $28,291 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $19,797
#|Description Savings
Cost
Status Electricity Usage Natural Gas One-time Revenue or Avoided Cost Electricity Usage Natural Gas One-time Revenue or Avoided Cost
$ kWh $ MMBtu $ $
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$695
Cost:
$1,500
$695 9,651 - - - - $695
9,651
kWh
-
-
MMBtu
-
-
$
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$4,680
Cost:
$2,150
$4,680 64,995 - - - - $4,680
64,995
kWh
-
-
MMBtu
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$15,125
Cost:
$43,167
$13,209 183,456 - - $1,916 - $13,209
183,456
kWh
-
-
MMBtu
$1,916
-
$
04: 2.2511 INSULATE BARE EQUIPMENT Savings:
$3,084
Cost:
$2,000
$3,084 42,833 - - - - $3,084
42,833
kWh
-
-
MMBtu
-
-
$
05: 2.2511 INSULATE BARE EQUIPMENT Savings:
$1,588
Cost:
$1,500
$1,588 22,050 - - - - $1,588
22,050
kWh
-
-
MMBtu
-
-
$
06: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$3,119
Cost:
$10,000
- - $3,119 3,058 - - -
-
kWh
$3,119
3,058
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$28,291
Cost:
$60,317
$23,256 322,985 $3,119 3,058 $1,916 - $23,256
322,985
kWh
$3,119
3,058
MMBtu
$1,916
-
$
TOTAL IMPLEMENTED Savings:
$19,797
Cost:
$46,667
$17,881 248,339 - - $1,916 - $17,881
248,339
kWh
-
-
MMBtu
$1,916
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas One-time Revenue or Avoided Cost Electricity Usage Natural Gas One-time Revenue or Avoided Cost