Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 2016
Principal Product Refrigeration And Heating Equipment
NAICS 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen
SIC 3714 - Motor Vehicle Parts And Accessories
Sales $10,000,000-$50,000,000
# of Employees 120
Plant Area (Sq.Ft.) 49,000
Annual Production 35,000 Units
Production Hrs. Annual 8,736
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $482,355 4,684,732 kWh $0.10
Natural Gas $42,995 6,935 MMBtu $6.20
TOTAL ENERGY COSTS $525,350
RECOMMENDED SAVINGS* $54,986 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$4,171
Cost:
$1,000
$4,171 41,710 - - $4,171
41,710
kWh
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$18,743
Cost:
$18,830
$18,743 187,425 - - $18,743
187,425
kWh
-
-
MMBtu
03: 2.7131 ADD AREA LIGHTING SWITCHES Savings:
$22,157
Cost:
$2,680
$22,157 221,570 - - $22,157
221,570
kWh
-
-
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$9,915
Cost:
$12,000
- - $9,915 1,598 -
-
kWh
$9,915
1,598
MMBtu
TOTAL RECOMMENDED Savings:
$54,986
Cost:
$34,510
$45,071 450,705 $9,915 1,598 $45,071
450,705
kWh
$9,915
1,598
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas