Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Utah |
---|---|
Assessment Year | 2006 |
Principal Product | envelopes |
NAICS | 322230 - Stationery Product Manufacturing |
SIC | 2677 - Envelopes |
Sales | $50,000,000-$100,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 187,000 |
Annual Production | 1,500,000,000 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | UT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $360,859 | 8,852,960 | kWh | $0.04 |
Electricity Demand | $162,709 | 16,216 | kW-months/year | $10.03 |
Electricity Fees | $31,977 | - | $ | - |
TOTAL ENERGY COSTS | $555,545 | |||
RECOMMENDED SAVINGS* | $442,590 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Water Consumption | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $23,520 Cost: $2,095 |
$19,010 | 465,937 | $6,070 | 511 | $(-1,560) | - | - | - | - | - |
$19,010 465,937 kWh |
$6,070 511 kW-months/year |
$(-1,560) - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2522 ISOLATE HOT OR COLD EQUIPMENT |
Savings: $4,260 Cost: $3,550 |
$2,860 | 70,100 | $1,400 | 118 | - | - | - | - | - | - |
$2,860 70,100 kWh |
$1,400 118 kW-months/year |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $5,350 Cost: $6,900 |
$4,260 | 104,400 | $1,090 | 92 | - | - | - | - | - | - |
$4,260 104,400 kWh |
$1,090 92 kW-months/year |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $126,380 Cost: $403,440 |
$119,330 | 2,924,010 | - | - | $7,560 | - | - | - | $(-510) | - |
$119,330 2,924,010 kWh |
- - kW-months/year |
$7,560 - $ |
- - $ |
$(-510) - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $2,640 Cost: - |
- | - | - | - | - | - | $2,640 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,640 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,440 Cost: $29,070 |
$2,460 | 60,313 | $980 | 83 | - | - | - | - | - | - |
$2,460 60,313 kWh |
$980 83 kW-months/year |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $277,000 Cost: $7,378,000 |
$180,650 | 4,426,500 | $96,350 | 8,108 | - | - | - | - | - | - |
$180,650 4,426,500 kWh |
$96,350 8,108 kW-months/year |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $442,590 Cost: $7,823,055 |
$328,570 | 8,051,260 | $105,890 | 8,912 | $6,000 | - | $2,640 | - | $(-510) | - | $328,570 8,051,260 kWh |
$105,890 8,912 kW-months/year |
$6,000 - $ |
$2,640 - $ |
$(-510) - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Water Consumption | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Water Consumption |