Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Utah |
---|---|
Assessment Year | 2019 |
Principal Product | Beer |
NAICS | 312120 - Breweries |
SIC | 2082 - Malt Beverages |
Sales | $5,000,000-$10,000,000 |
# of Employees | 40 |
Plant Area (Sq.Ft.) | 20,000 |
Annual Production | 30,000 Units |
Production Hrs. Annual | 8,760 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $22,867 | 617,520 | kWh | $0.04 |
Electricity Demand | $37,310 | 1,654 | kW-months/year | $22.56 |
Natural Gas | $31,277 | 5,434 | MMBtu | $5.76 |
TOTAL ENERGY COSTS | $91,454 | |||
RECOMMENDED SAVINGS* | $63,595 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $9,595 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Gaseous Waste | Electricity Usage | Electricity Demand | Natural Gas | Gaseous Waste | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.1175 USE A DIFFERENT OR RECYCLED RAW MATERIAL |
Savings: $54,000 Cost: $300,000 |
- | - | - | - | - | - | $54,000 | 416,000 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$54,000 416,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $3,521 Cost: $2,917 |
$1,921 | 51,767 | $1,600 | 71 | - | - | - | - |
$1,921 51,767 kWh |
$1,600 71 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,684 Cost: $7,000 |
$705 | 19,008 | $1,979 | 88 | - | - | - | - |
$705 19,008 kWh |
$1,979 88 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,746 Cost: $1,200 |
$582 | 15,693 | $1,164 | 52 | - | - | - | - |
$582 15,693 kWh |
$1,164 52 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,081 Cost: $1,800 |
$415 | 11,195 | $666 | 30 | - | - | - | - |
$415 11,195 kWh |
$666 30 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $130 Cost: - |
$130 | 3,510 | - | - | - | - | - | - |
$130 3,510 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $433 Cost: $400 |
- | - | - | - | $433 | 75 | - | - |
- - kWh |
- - kW-months/year |
$433 75 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $63,595 Cost: $313,317 |
$3,753 | 101,173 | $5,409 | 240 | $433 | 75 | $54,000 | 416,000 | $3,753 101,173 kWh |
$5,409 240 kW-months/year |
$433 75 MMBtu |
$54,000 416,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $9,595 Cost: $13,317 |
$3,753 | 101,173 | $5,409 | 240 | $433 | 75 | - | - | $3,753 101,173 kWh |
$5,409 240 kW-months/year |
$433 75 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Gaseous Waste | Electricity Usage | Electricity Demand | Natural Gas | Gaseous Waste |