Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Utah |
---|---|
Assessment Year | 2019 |
Principal Product | Auto parts |
NAICS | 336390 - Other Motor Vehicle Parts Manufacturing |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $10,000,000-$50,000,000 |
# of Employees | 147 |
Plant Area (Sq.Ft.) | 211,035 |
Annual Production | 730 Units |
Production Hrs. Annual | 2,086 |
Location (State) | UT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $43,628 | 869,149 | kWh | $0.05 |
Electricity Demand | $49,524 | 3,632 | kW-months/year | $13.64 |
Electricity Fees | $4,091 | - | $ | - |
Natural Gas | $63,500 | 8,469 | MMBtu | $7.50 |
TOTAL ENERGY COSTS | $160,744 | |||
RECOMMENDED SAVINGS* | $45,274 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $45,274 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $15,321 Cost: $68,567 |
$5,763 | 158,188 | $9,558 | 605 | - | - | - | - |
$5,763 158,188 kWh |
$9,558 605 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,079 Cost: $4,000 |
- | - | $2,079 | 243 | - | - | - | - |
- - kWh |
$2,079 243 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $12,670 Cost: $22,920 |
- | - | - | - | - | - | $12,670 | 1,790 |
- - kWh |
- - kW-months/year |
- - $ |
$12,670 1,790 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $9,094 Cost: $8,488 |
$5,626 | 156,278 | $3,468 | 214 | - | - | - | - |
$5,626 156,278 kWh |
$3,468 214 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $314 Cost: $218 |
$314 | 8,599 | - | - | - | - | - | - |
$314 8,599 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $3,916 Cost: $3,800 |
$3,524 | 32,036 | $392 | 66 | - | - | - | - |
$3,524 32,036 kWh |
$392 66 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $1,880 Cost: $650 |
- | - | - | - | $1,880 | - | - | - |
- - kWh |
- - kW-months/year |
$1,880 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $45,274 Cost: $108,643 |
$15,227 | 355,101 | $15,497 | 1,128 | $1,880 | - | $12,670 | 1,790 | $15,227 355,101 kWh |
$15,497 1,128 kW-months/year |
$1,880 - $ |
$12,670 1,790 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $45,274 Cost: $108,643 |
$15,227 | 355,101 | $15,497 | 1,128 | $1,880 | - | $12,670 | 1,790 | $15,227 355,101 kWh |
$15,497 1,128 kW-months/year |
$1,880 - $ |
$12,670 1,790 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |