Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Utah |
---|---|
Assessment Year | 2021 |
Principal Product | Treated Wastewater |
NAICS | 237110 - Water and Sewer Line and Related Structures Construction |
SIC | 1623 - Water, Sewer, And Utility Lines |
Sales | $1,000,000-$5,000,000 |
# of Employees | 6 |
Plant Area (Sq.Ft.) | 71,000 |
Annual Production | 803,534 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | UT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $142,659 | 3,973,798 | kWh | $0.04 |
Electricity Demand | $142,659 | 8,784 | kW-months/year | $16.24 |
Natural Gas | $20,198 | 2,889 | MMBtu | $6.99 |
TOTAL ENERGY COSTS | $305,517 | |||
RECOMMENDED SAVINGS* | $39,972 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $32,769 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $19,749 Cost: $38,000 |
$12,193 | 339,645 | $7,556 | 465 | - | - | - | - |
$12,193 339,645 kWh |
$7,556 465 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8113 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER |
Savings: $7,428 Cost: $14,400 |
- | - | - | - | $7,428 | - | - | - |
- - kWh |
- - kW-months/year |
$7,428 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.9113 USE SOLAR HEAT FOR HEAT |
Savings: $4,877 Cost: $10,800 |
- | - | - | - | - | - | $4,877 | 698 |
- - kWh |
- - kW-months/year |
- - $ |
$4,877 698 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $3,303 Cost: $150 |
- | - | - | - | - | - | $3,303 | 473 |
- - kWh |
- - kW-months/year |
- - $ |
$3,303 473 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,175 Cost: $4,613 |
$1,154 | 32,132 | $1,021 | 63 | - | - | - | - |
$1,154 32,132 kWh |
$1,021 63 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,172 Cost: $2,482 |
$1,341 | 37,354 | $831 | 51 | - | - | - | - |
$1,341 37,354 kWh |
$831 51 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $154 Cost: $71 |
$154 | 4,287 | - | - | - | - | - | - |
$154 4,287 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $114 Cost: $50 |
$114 | 3,174 | - | - | - | - | - | - |
$114 3,174 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $39,972 Cost: $70,566 |
$14,955 | 416,592 | $9,408 | 579 | $7,428 | - | $8,180 | 1,171 | $14,955 416,592 kWh |
$9,408 579 kW-months/year |
$7,428 - $ |
$8,180 1,171 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $32,769 Cost: $57,213 |
$13,461 | 374,951 | $8,577 | 528 | $7,428 | - | $3,303 | 473 | $13,461 374,951 kWh |
$8,577 528 kW-months/year |
$7,428 - $ |
$3,303 473 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |