Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Utah
Assessment Year 2023
Principal Product Heating elements
NAICS 333994 - Industrial Process Furnace and Oven Manufacturing
SIC 3567 - Industrial Furnaces And Ovens
Sales $10,000,000-$50,000,000
# of Employees 250
Plant Area (Sq.Ft.) 184,600
Annual Production 400,000 Units
Production Hrs. Annual 8,760
Location (State) UT
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $153,590 4,654,255 kWh $0.03
Electricity Demand $222,987 11,596 kW-months/year $19.23
Natural Gas $125,277 25,370 MMBtu $4.94
TOTAL ENERGY COSTS $501,854
RECOMMENDED SAVINGS* $78,830 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $73,135
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas Electricity Usage Electricity Demand Electricity Fees Natural Gas
$ kWh $ kW-months/year $ $ $ MMBtu
01: 2.7234 USE HEAT PUMP FOR SPACE CONDITIONING Savings:
$67,069
Cost:
-
$6,591 199,738 - - - - $60,478 12,230 $6,591
199,738
kWh
-
-
kW-months/year
-
-
$
$60,478
12,230
MMBtu
02: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$3,986
Cost:
$13,500
- - - - $3,986 - - - -
-
kWh
-
-
kW-months/year
$3,986
-
$
-
-
MMBtu
03: 2.2425 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER Savings:
$2,450
Cost:
$3,366
- - - - - - $2,450 333 -
-
kWh
-
-
kW-months/year
-
-
$
$2,450
333
MMBtu
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$3,245
Cost:
$3,810
$227 6,869 $3,018 157 - - - - $227
6,869
kWh
$3,018
157
kW-months/year
-
-
$
-
-
MMBtu
05: 2.6241 REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY Savings:
$1,160
Cost:
$50
$1,160 35,100 - - - - - - $1,160
35,100
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$920
Cost:
$1,200
$708 21,465 $212 11 - - - - $708
21,465
kWh
$212
11
kW-months/year
-
-
$
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$78,830
Cost:
$21,926
$8,686 263,172 $3,230 168 $3,986 - $62,928 12,563 $8,686
263,172
kWh
$3,230
168
kW-months/year
$3,986
-
$
$62,928
12,563
MMBtu
TOTAL IMPLEMENTED Savings:
$73,135
Cost:
$14,750
$8,459 256,303 $212 11 $3,986 - $60,478 12,230 $8,459
256,303
kWh
$212
11
kW-months/year
$3,986
-
$
$60,478
12,230
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu
Electricity Usage Electricity Demand Electricity Fees Natural Gas Electricity Usage Electricity Demand Electricity Fees Natural Gas