Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Utah |
---|---|
Assessment Year | 2023 |
Principal Product | Ice cream |
NAICS | 311520 - Ice Cream and Frozen Dessert Manufacturing |
SIC | 2024 - Ice Cream And Frozen Desserts |
Sales | $1,000,000-$5,000,000 |
# of Employees | 8 |
Plant Area (Sq.Ft.) | 43,000 |
Annual Production | 450,000 Pounds |
Production Hrs. Annual | 2,000 |
Location (State) | UT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $148,458 | 1,587,936 | kWh | $0.09 |
Other Energy | $81,198 | 5,497 | MMBtu | $14.77 |
TOTAL ENERGY COSTS | $229,656 | |||
RECOMMENDED SAVINGS* | $200,364 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $200,364 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Other Energy | Water Usage | Increase in Production | Electricity Usage | Natural Gas | Other Energy | Water Usage | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | $ | Tgal | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.452 ELIMINATE SHIFT |
Savings: $171,281 Cost: $5,500 |
- | - | - | - | - | - | - | - | $171,281 | - |
- - kWh |
- - MMBtu |
- - MMBtu |
- - Tgal |
$171,281 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $16,735 Cost: $51,600 |
- | - | - | - | $16,735 | 7,534 | - | - | - | - |
- - kWh |
- - MMBtu |
$16,735 7,534 MMBtu |
- - Tgal |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $8,766 Cost: $26,767 |
$1,056 | 10,436 | - | - | - | - | $7,710 | 7,229 | - | - |
$1,056 10,436 kWh |
- - MMBtu |
- - MMBtu |
$7,710 7,229 Tgal |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $3,305 Cost: $11,743 |
- | - | $2,577 | 229 | - | - | $728 | 196 | - | - |
- - kWh |
$2,577 229 MMBtu |
- - MMBtu |
$728 196 Tgal |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $277 Cost: $142 |
$277 | 2,733 | - | - | - | - | - | - | - | - |
$277 2,733 kWh |
- - MMBtu |
- - MMBtu |
- - Tgal |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $200,364 Cost: $95,752 |
$1,333 | 13,169 | $2,577 | 229 | $16,735 | 7,534 | $8,438 | 7,425 | $171,281 | - | $1,333 13,169 kWh |
$2,577 229 MMBtu |
$16,735 7,534 MMBtu |
$8,438 7,425 Tgal |
$171,281 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $200,364 Cost: $95,752 |
$1,333 | 13,169 | $2,577 | 229 | $16,735 | 7,534 | $8,438 | 7,425 | $171,281 | - | $1,333 13,169 kWh |
$2,577 229 MMBtu |
$16,735 7,534 MMBtu |
$8,438 7,425 Tgal |
$171,281 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | $ | Tgal | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Other Energy | Water Usage | Increase in Production | Electricity Usage | Natural Gas | Other Energy | Water Usage | Increase in Production |