Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Utah |
---|---|
Assessment Year | 2024 |
Principal Product | Pre-Impregnanted Carbon Fiber |
NAICS | 335991 - Carbon and Graphite Product Manufacturing |
SIC | 3624 - Carbon And Graphite Products |
Sales | $100,000,000-$500,000,000 |
# of Employees | 500 |
Plant Area (Sq.Ft.) | 1,500,000 |
Annual Production | 200,000 Thousand Feet |
Production Hrs. Annual | 8,760 |
Location (State) | UT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $973,527 | 33,596,906 | kWh | $0.03 |
Electricity Demand | $88,792 | 5,570 | kW-months/year | $15.94 |
Electricity Fees | $328,903 | - | $ | - |
Natural Gas | $1,698,070 | 181,990 | MMBtu | $9.33 |
TOTAL ENERGY COSTS | $3,089,292 | |||
RECOMMENDED SAVINGS* | $240,993 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $139,774 Cost: $4,000 |
$82,199 | 2,834,435 | $57,575 | 3,612 | - | - |
$82,199 2,834,435 kWh |
$57,575 3,612 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2153 CLOSE OFF UNNEEDED STEAM LINES |
Savings: $10,220 Cost: $4,400 |
- | - | - | - | $10,220 | 1,099 |
- - kWh |
- - kW-months/year |
$10,220 1,099 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $14,164 Cost: $37,300 |
$8,062 | 278,000 | $6,102 | 383 | - | - |
$8,062 278,000 kWh |
$6,102 383 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $5,187 Cost: $5,143 |
$2,891 | 99,700 | $2,295 | 144 | - | - |
$2,891 99,700 kWh |
$2,295 144 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $8,004 Cost: $11,422 |
$6,639 | 228,947 | $1,365 | 86 | - | - |
$6,639 228,947 kWh |
$1,365 86 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $21,730 Cost: $82,100 |
$15,800 | 543,000 | $5,930 | 372 | - | - |
$15,800 543,000 kWh |
$5,930 372 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $6,520 Cost: $9,510 |
$6,520 | 225,000 | - | - | - | - |
$6,520 225,000 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $10,658 Cost: $13,800 |
$6,116 | 210,884 | $4,543 | 285 | - | - |
$6,116 210,884 kWh |
$4,543 285 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $12,487 Cost: $68,600 |
$7,131 | 246,000 | $5,356 | 336 | - | - |
$7,131 246,000 kWh |
$5,356 336 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $12,250 Cost: $84,300 |
$6,990 | 241,036 | $5,260 | 330 | - | - |
$6,990 241,036 kWh |
$5,260 330 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $240,993 Cost: $320,575 |
$142,348 | 4,907,002 | $88,425 | 5,547 | $10,220 | 1,099 | $142,348 4,907,002 kWh |
$88,425 5,547 kW-months/year |
$10,220 1,099 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |