Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Utah |
---|---|
Assessment Year | 2024 |
Principal Product | NA |
NAICS | 721110 - Hotels (except Casino Hotels) and Motels |
SIC | 7011 - Hotels And Motels |
Sales | <$500,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 365,000 |
Annual Production | 1 Units |
Production Hrs. Annual | 8,760 |
Location (State) | UT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $223,662 | 6,766,550 | kWh | $0.03 |
Electricity Demand | $219,279 | 11,342 | kW-months/year | $19.33 |
Natural Gas | $470,461 | 52,866 | MMBtu | $8.90 |
TOTAL ENERGY COSTS | $913,401 | |||
RECOMMENDED SAVINGS* | $63,895 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $40,220 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7229 AIR CONDITION ONLY SPACE NECESSARY |
Savings: $26,330 Cost: $19,500 |
$4,700 | 142,430 | - | - | - | - | $21,630 | 2,430 |
$4,700 142,430 kWh |
- - kW-months/year |
- - $ |
$21,630 2,430 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3137 USE POWER DURING OFF-PEAK PERIODS |
Savings: $15,800 Cost: $13,000 |
- | - | - | - | $15,800 | - | - | - |
- - kWh |
- - kW-months/year |
$15,800 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2514 COVER OPEN TANKS |
Savings: $9,190 Cost: $7,340 |
- | - | - | - | - | - | $9,190 | 1,030 |
- - kWh |
- - kW-months/year |
- - $ |
$9,190 1,030 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,631 Cost: $22,338 |
$2,574 | 77,997 | $2,057 | 106 | - | - | - | - |
$2,574 77,997 kWh |
$2,057 106 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,244 Cost: $14,145 |
$1,686 | 51,077 | $1,558 | 81 | - | - | - | - |
$1,686 51,077 kWh |
$1,558 81 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $2,800 Cost: $6,300 |
$2,800 | 84,950 | - | - | - | - | - | - |
$2,800 84,950 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $1,900 Cost: $6,000 |
- | - | - | - | $1,900 | - | - | - |
- - kWh |
- - kW-months/year |
$1,900 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $63,895 Cost: $88,623 |
$11,760 | 356,454 | $3,615 | 187 | $17,700 | - | $30,820 | 3,460 | $11,760 356,454 kWh |
$3,615 187 kW-months/year |
$17,700 - $ |
$30,820 3,460 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $40,220 Cost: $39,140 |
$7,500 | 227,380 | - | - | $1,900 | - | $30,820 | 3,460 | $7,500 227,380 kWh |
- - kW-months/year |
$1,900 - $ |
$30,820 3,460 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |