IAC logo
IAC Assessment: UU0247
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UU0247
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Utah
Assessment Year 2024
Principal Product Truck and Trailer Rebuilds
NAICS 333924 - Industrial Truck, Tractor, Trailer, and Stacker Machinery Manufacturing
SIC 3537 - Industrial Trucks And Tractors
Sales $1,000,000-$5,000,000
# of Employees 22
Plant Area (Sq.Ft.) 46,820
Annual Production 125 Units
Production Hrs. Annual 2,241
Location (State) ID
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $14,895 328,442 kWh $0.05
Electricity Demand $9,098 1,820 kW-months/year $5.00
Natural Gas $19,247 2,475 MMBtu $7.78
Fuel Oil #1 $52,408 1,123 MMBtu $46.67
Fuel Oil #2 $6,471 1,956 MMBtu $3.31
Other Energy $1,230 1 MMBtu $1,230.00
TOTAL ENERGY COSTS $103,349
RECOMMENDED SAVINGS* $209,664 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas By-product Production Electricity Usage Electricity Demand Natural Gas By-product Production
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$5,970
Cost:
$3,000
$5,970 131,510 - - - - - - $5,970
131,510
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,770
Cost:
$9,500
- - - - $1,770 230 - - -
-
kWh
-
-
kW-months/year
$1,770
230
MMBtu
-
-
$
03: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT Savings:
$200,000
Cost:
$717,040
- - - - - - $200,000 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$200,000
-
$
04: 2.2427 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS Savings:
$1,060
Cost:
$1,950
- - - - $1,060 136 - - -
-
kWh
-
-
kW-months/year
$1,060
136
MMBtu
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$864
Cost:
$7,540
$575 12,730 $289 58 - - - - $575
12,730
kWh
$289
58
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$209,664
Cost:
$739,030
$6,545 144,240 $289 58 $2,830 366 $200,000 - $6,545
144,240
kWh
$289
58
kW-months/year
$2,830
366
MMBtu
$200,000
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas By-product Production Electricity Usage Electricity Demand Natural Gas By-product Production