Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Utah
Assessment Year 2025
Principal Product Treated Groundwater
NAICS 221310 - Water Supply and Irrigation Systems
SIC 4941 - Water Supply
Sales $1,000,000-$5,000,000
# of Employees 5
Plant Area (Sq.Ft.) 11,000
Annual Production 990,000 Thousand Gallons
Production Hrs. Annual 8,760
Location (State) UT
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $115,820 2,407,893 kWh $0.05
Electricity Demand $37,298 4,572 kW-months/year $8.16
Electricity Fees $24,773 - $ -
TOTAL ENERGY COSTS $177,891
RECOMMENDED SAVINGS* $91,229 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Personnel Changes Electricity Usage Electricity Demand Personnel Changes
$ kWh $ kW-months/year $ $
01: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY Savings:
$30,600
Cost:
$110,000
$25,364 528,000 $7,636 936 $(-2,400) - $25,364
528,000
kWh
$7,636
936
kW-months/year
$(-2,400)
-
$
02: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$20,500
Cost:
$110,000
$17,773 369,000 $5,727 702 $(-3,000) - $17,773
369,000
kWh
$5,727
702
kW-months/year
$(-3,000)
-
$
03: 4.454 MODIFY STARTUP/SHUTDOWN TIMES Savings:
$2,950
Cost:
$3,600
$(-140) (-2,900) $5,490 653 $(-2,400) - $(-140)
(-2,900)
kWh
$5,490
653
kW-months/year
$(-2,400)
-
$
04: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$28,400
Cost:
$657,000
$28,400 447,000 - - - - $28,400
447,000
kWh
-
-
kW-months/year
-
-
$
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$8,440
Cost:
$14,700
$6,588 137,000 $1,852 227 - - $6,588
137,000
kWh
$1,852
227
kW-months/year
-
-
$
06: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$339
Cost:
$990
$339 9,690 - - - - $339
9,690
kWh
-
-
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$91,229
Cost:
$896,290
$78,324 1,487,790 $20,705 2,518 $(-7,800) - $78,324
1,487,790
kWh
$20,705
2,518
kW-months/year
$(-7,800)
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Personnel Changes Electricity Usage Electricity Demand Personnel Changes