IAC logo
IAC Assessment: UW0011
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UW0011
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Washington
Assessment Year 2008
Principal Product Wine
NAICS 312130 - Wineries
SIC 2084 - Wines, Brandy, And Brandy Spirits
Sales $10,000,000-$50,000,000
# of Employees 70
Plant Area (Sq.Ft.) 30,450
Annual Production 500,000 Pieces
Production Hrs. Annual 4,680
Location (State) WA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $61,922 926,760 kWh $0.07
Electricity Demand $16,223 2,465 kW-months/year $6.58
Electricity Fees $1,598 - $ -
Natural Gas $29,709 2,539 MMBtu $11.70
TOTAL ENERGY COSTS $130,216
RECOMMENDED SAVINGS* $37,096 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz) Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz)
$ kWh $ kW-months/year $ MMBtu $ lb
01: 2.1224 REPLACE BOILER Savings:
$8,882
Cost:
$23,870
- - - - $8,882 759 - - -
-
kWh
-
-
kW-months/year
$8,882
759
MMBtu
-
-
lb
02: 2.2511 INSULATE BARE EQUIPMENT Savings:
$7,908
Cost:
$15,906
$7,908 130,903 - - - - - - $7,908
130,903
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
lb
03: 3.6125 SELL COMBUSTIBLE WASTE Savings:
$5,774
Cost:
-
- - - - - - $5,774 256,660 -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$5,774
256,660
lb
04: 2.9112 USE SOLAR HEAT TO HEAT WATER Savings:
$5,523
Cost:
$20,275
- - - - $5,523 691 - - -
-
kWh
-
-
kW-months/year
$5,523
691
MMBtu
-
-
lb
05: 2.7145 INSTALL SKYLIGHTS Savings:
$5,089
Cost:
$26,250
$4,464 63,540 $625 15 - - - - $4,464
63,540
kWh
$625
15
kW-months/year
-
-
MMBtu
-
-
lb
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,444
Cost:
-
$1,979 32,760 $465 84 - - - - $1,979
32,760
kWh
$465
84
kW-months/year
-
-
MMBtu
-
-
lb
07: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,476
Cost:
$300
$1,476 20,152 - - - - - - $1,476
20,152
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
lb
TOTAL RECOMMENDED Savings:
$37,096
Cost:
$86,601
$15,827 247,355 $1,090 99 $14,405 1,450 $5,774 256,660 $15,827
247,355
kWh
$1,090
99
kW-months/year
$14,405
1,450
MMBtu
$5,774
256,660
lb
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
lb
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ lb
Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz) Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz)