IAC logo
IAC Assessment: UW0030
Sponsored by:
EERE AMO
IAC logo
IAC Assessment: UW0030
IAC Center University of Washington
Assessment Year 2009
Principal Product Pulp and Paper Products
NAICS 322110 - Pulp Mills
SIC 2611 - Pulp Mills
Sales >$500,000,000
# of Employees 350
Plant Area (Sq.Ft.) 250,000
Annual Production 800,000 Tons
Production Hrs. Annual 7,358
Location (State) WA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $3,440,976 38,457,000 kWh $0.09
Electricity Demand $342,040 204,000 kW-months/year $1.68
TOTAL ENERGY COSTS $3,783,016
RECOMMENDED SAVINGS* $324,407 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Fuel Oil #6 Electricity Usage Electricity Demand Fuel Oil #6
$ kWh $ kW-months/year $ MMBtu
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$134,729
Cost:
$705,718
$124,234 4,141,132 $10,495 472 - - $124,234
4,141,132
kWh
$10,495
472
kW-months/year
-
-
MMBtu
02: 2.1232 KEEP BOILER TUBES CLEAN Savings:
$115,460
Cost:
$50,000
- - - - $115,460 11,546 -
-
kWh
-
-
kW-months/year
$115,460
11,546
MMBtu
03: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$74,218
Cost:
$166,366
$71,728 1,769,000 $2,490 1,452 - - $71,728
1,769,000
kWh
$2,490
1,452
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$324,407
Cost:
$922,084
$195,962 5,910,132 $12,985 1,924 $115,460 11,546 $195,962
5,910,132
kWh
$12,985
1,924
kW-months/year
$115,460
11,546
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Fuel Oil #6 Electricity Usage Electricity Demand Fuel Oil #6