IAC logo
IAC Assessment: UW2315
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UW2315
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Washington
Assessment Year 2023
Principal Product batch/mix plants in manufacturing concrete.
NAICS 327320 - Ready-Mix Concrete Manufacturing
SIC 3273 - Ready-mixed Concrete
Sales $10,000,000-$50,000,000
# of Employees 5
Plant Area (Sq.Ft.) 6,065
Annual Production 600,000 Tons
Production Hrs. Annual 3,120
Location (State) WA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $142,700 1,731,990 kWh $0.08
Electricity Demand $81,279 13,510 kW-months/year $6.02
Electricity Fees $45,061 - $ -
Natural Gas $24,956 4,181 MMBtu $5.97
TOTAL ENERGY COSTS $293,996
RECOMMENDED SAVINGS* $37,636 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$6,189
Cost:
$1,896
$6,189 75,202 - - - - $6,189
75,202
kWh
-
-
kW-months/year
-
-
MMBtu
02: 2.1116 IMPROVE COMBUSTION CONTROL CAPABILITY Savings:
$30,104
Cost:
$300,000
- - - - $30,104 5,051 -
-
kWh
-
-
kW-months/year
$30,104
5,051
MMBtu
03: 2.7493 USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES Savings:
$1,343
Cost:
$10,879
$1,211 14,709 $132 22 - - $1,211
14,709
kWh
$132
22
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$37,636
Cost:
$312,775
$7,400 89,911 $132 22 $30,104 5,051 $7,400
89,911
kWh
$132
22
kW-months/year
$30,104
5,051
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas