Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 1996 |
Principal Product | Projectile and Cartrige Cases |
NAICS | n/a |
SIC | 3483 - Ammunition, Exc. For Small Arms, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 4,000,000 Pieces |
Production Hrs. Annual | 4,125 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $237,114 | 9,232,122 | kWh | $0.03 |
Electricity Demand | $172,017 | 24,172 | kW-months/year | $7.12 |
Electricity Fees | $5,637 | - | $ | - |
Natural Gas | $265,781 | 100,386 | MMBtu | $2.65 |
TOTAL ENERGY COSTS | $680,549 | |||
RECOMMENDED SAVINGS* | $65,120 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,958 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS |
Savings: $27,900 Cost: $4,000 |
- | - | - | - | - | - | - | - | $27,900 | 374 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$27,900 374 gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6232 INSTALL SET-BACK TIMERS |
Savings: $26,926 Cost: $1,100 |
- | - | - | - | $26,926 | 10,161 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$26,926 10,161 MMBtu |
- - Tgal |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $3,375 Cost: - |
- | - | - | - | - | - | - | - | - | - | $3,375 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
$3,375 - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4151 MINIMIZE WATER USAGE |
Savings: $1,975 Cost: - |
- | - | - | - | - | - | $1,975 | 2,100,000 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,975 2,100,000 Tgal |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $1,431 Cost: $2,160 |
- | - | - | - | $1,431 | 540 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,431 540 MMBtu |
- - Tgal |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE |
Savings: $1,370 Cost: $5,000 |
$601 | 22,274 | $769 | 108 | - | - | - | - | - | - | - | - |
$601 22,274 kWh |
$769 108 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $596 Cost: $700 |
- | - | - | - | $596 | 255 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$596 255 MMBtu |
- - Tgal |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $569 Cost: - |
- | - | - | - | $569 | 215 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$569 215 MMBtu |
- - Tgal |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $370 Cost: $675 |
$149 | 5,569 | $221 | 31 | - | - | - | - | - | - | - | - |
$149 5,569 kWh |
$221 31 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $335 Cost: - |
$164 | 6,155 | $171 | 24 | - | - | - | - | - | - | - | - |
$164 6,155 kWh |
$171 24 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $273 Cost: $500 |
- | - | - | - | $273 | 103 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$273 103 MMBtu |
- - Tgal |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $65,120 Cost: $14,135 |
$914 | 33,998 | $1,161 | 163 | $29,795 | 11,274 | $1,975 | 2,100,000 | $27,900 | 374 | $3,375 | - | $914 33,998 kWh |
$1,161 163 kW-months/year |
$29,795 11,274 MMBtu |
$1,975 2,100,000 Tgal |
$27,900 374 gal |
$3,375 - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,958 Cost: $500 |
$164 | 6,155 | $171 | 24 | $273 | 103 | $1,975 | 2,100,000 | - | - | $3,375 | - | $164 6,155 kWh |
$171 24 kW-months/year |
$273 103 MMBtu |
$1,975 2,100,000 Tgal |
- - gal |
$3,375 - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) |