Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 1998 |
Principal Product | Napkins and Place Mats |
NAICS | n/a |
SIC | 2676 - Sanitary Paper Products |
Sales | $10,000,000-$50,000,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 120,000 |
Annual Production | 2,147,483,647 Pieces |
Production Hrs. Annual | 4,500 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $121,256 | 3,477,140 | kWh | $0.03 |
Electricity Demand | $25,108 | 5,061 | kW-months/year | $4.96 |
Electricity Fees | $4,703 | - | $ | - |
Natural Gas | $32,000 | 5,817 | MMBtu | $5.50 |
TOTAL ENERGY COSTS | $192,952 | |||
RECOMMENDED SAVINGS* | $75,988 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $17,186 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $54,000 Cost: $20,000 |
- | - | - | - | - | - | $54,000 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$54,000 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.7137 REPLACE CLOTH RAGS WITH PAPER TOWELS |
Savings: $7,600 Cost: - |
- | - | - | - | - | - | - | - | $7,600 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$7,600 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $5,103 Cost: $1,400 |
- | - | - | - | $5,103 | 928 | - | - | - | - |
- - kWh |
- - kW-months/year |
$5,103 928 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $4,015 Cost: $8,000 |
$(-388) | (-11,430) | - | - | $4,403 | 800 | - | - | - | - |
$(-388) (-11,430) kWh |
- - kW-months/year |
$4,403 800 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $4,802 Cost: $7,200 |
$3,029 | 90,270 | $1,773 | 340 | - | - | - | - | - | - |
$3,029 90,270 kWh |
$1,773 340 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $468 Cost: $640 |
$364 | 9,965 | $104 | 20 | - | - | - | - | - | - |
$364 9,965 kWh |
$104 20 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $75,988 Cost: $37,240 |
$3,005 | 88,805 | $1,877 | 360 | $9,506 | 1,728 | $54,000 | - | $7,600 | - | $3,005 88,805 kWh |
$1,877 360 kW-months/year |
$9,506 1,728 MMBtu |
$54,000 - $ |
$7,600 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $17,186 Cost: $10,040 |
$(-24) | (-1,465) | $104 | 20 | $9,506 | 1,728 | - | - | $7,600 | - | $(-24) (-1,465) kWh |
$104 20 kW-months/year |
$9,506 1,728 MMBtu |
- - $ |
$7,600 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes |