Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2000 |
Principal Product | Bolts and Screws |
NAICS | n/a |
SIC | 3452 - Bolts, Nuts, Rivets, And Washers |
Sales | $10,000,000-$50,000,000 |
# of Employees | 86 |
Plant Area (Sq.Ft.) | 148,000 |
Annual Production | 6,500,000 Pounds |
Production Hrs. Annual | 2,750 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $39,762 | 1,106,096 | kWh | $0.04 |
Electricity Demand | $56,049 | 4,597 | kW-months/year | $12.19 |
Electricity Fees | $9,305 | - | $ | - |
Natural Gas | $26,739 | 6,225 | MMBtu | $4.30 |
TOTAL ENERGY COSTS | $172,951 | |||
RECOMMENDED SAVINGS* | $76,825 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,255 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.521 CLEAR AND RENT EXISTING SPACE |
Savings: $34,613 Cost: - |
- | - | - | - | - | - | - | - | $34,613 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$34,613 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.515 INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE |
Savings: $30,575 Cost: $2,955 |
- | - | - | - | - | - | - | - | $30,575 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$30,575 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.7137 REPLACE CLOTH RAGS WITH PAPER TOWELS |
Savings: $3,255 Cost: - |
- | - | - | - | - | - | - | - | $3,255 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$3,255 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $2,441 Cost: $7,400 |
$(-247) | (-6,448) | - | - | $2,688 | 625 | - | - | - | - |
$(-247) (-6,448) kWh |
- - kW-months/year |
$2,688 625 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $2,130 Cost: - |
- | - | - | - | - | - | $2,130 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$2,130 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,218 Cost: $740 |
$593 | 15,826 | $625 | 49 | - | - | - | - | - | - |
$593 15,826 kWh |
$625 49 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,297 Cost: $1,410 |
$(-26) | (-586) | - | - | $1,323 | 308 | - | - | - | - |
$(-26) (-586) kWh |
- - kW-months/year |
$1,323 308 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $669 Cost: $450 |
$669 | 17,585 | - | - | - | - | - | - | - | - |
$669 17,585 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $627 Cost: $500 |
- | - | - | - | $627 | 146 | - | - | - | - |
- - kWh |
- - kW-months/year |
$627 146 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $76,825 Cost: $13,455 |
$989 | 26,377 | $625 | 49 | $4,638 | 1,079 | $2,130 | - | $68,443 | - | $989 26,377 kWh |
$625 49 kW-months/year |
$4,638 1,079 MMBtu |
$2,130 - lb |
$68,443 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,255 Cost: - |
- | - | - | - | - | - | - | - | $3,255 | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$3,255 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes |