Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2014 |
Principal Product | Contactors and Soft Starters |
NAICS | 541712 - Research and Development in the Physical, Engineering, and Life Sciences (except Biotechnology) |
SIC | 5063 - Electrical Apparatus And Equipment |
Sales | <$500,000 |
# of Employees | 189 |
Plant Area (Sq.Ft.) | 90,000 |
Annual Production | 0 Pieces |
Production Hrs. Annual | 6,120 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $153,276 | 2,236,500 | kWh | $0.07 |
Electricity Demand | $62,762 | 4,757 | kW-months/year | $13.19 |
Natural Gas | $28,854 | 4,032 | MMBtu | $7.16 |
TOTAL ENERGY COSTS | $247,686 | |||
RECOMMENDED SAVINGS* | $18,856 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,201 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $8,511 Cost: - |
$7,668 | 111,939 | $843 | 64 | - | - | - | - | - | - |
$7,668 111,939 kWh |
$843 64 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6127 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT |
Savings: $1,524 Cost: $330 |
$1,197 | 17,464 | $327 | 25 | - | - | - | - | - | - |
$1,197 17,464 kWh |
$327 25 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $2,335 Cost: $10,000 |
$1,839 | 26,840 | $496 | 38 | - | - | - | - | - | - |
$1,839 26,840 kWh |
$496 38 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $2,363 Cost: $2,000 |
$2,098 | 30,628 | - | - | $265 | 37 | - | - | - | - |
$2,098 30,628 kWh |
- - kW-months/year |
$265 37 MMBtu |
- - Tgal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $934 Cost: - |
$934 | 11,145 | - | - | - | - | - | - | - | - |
$934 11,145 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,194 Cost: $4,048 |
$1,154 | 18,310 | $40 | 3 | - | - | - | - | - | - |
$1,154 18,310 kWh |
$40 3 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $232 Cost: $720 |
$133 | 1,934 | $99 | 8 | - | - | - | - | - | - |
$133 1,934 kWh |
$99 8 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4151 MINIMIZE WATER USAGE |
Savings: $1,764 Cost: $6,315 |
- | - | - | - | - | - | $1,194 | 152 | $570 | 151,939 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,194 152 Tgal |
$570 151,939 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $18,856 Cost: $23,413 |
$15,023 | 218,260 | $1,805 | 137 | $265 | 37 | $1,194 | 152 | $570 | 151,939 | $15,023 218,260 kWh |
$1,805 137 kW-months/year |
$265 37 MMBtu |
$1,194 152 Tgal |
$570 151,939 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,201 Cost: $1,050 |
$9,932 | 142,482 | $1,269 | 96 | - | - | - | - | - | - | $9,932 142,482 kWh |
$1,269 96 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) |