Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2015 |
Principal Product | Raw Forging |
NAICS | 332111 - Iron and Steel Forging |
SIC | 3462 - Iron And Steel Forgings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 110 |
Plant Area (Sq.Ft.) | 125,000 |
Annual Production | 14,000,000 Pounds |
Production Hrs. Annual | 4,080 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $619,670 | 9,817,878 | kWh | $0.06 |
Electricity Demand | $279,152 | 38,504 | kW-months/year | $7.25 |
Electricity Fees | $28,231 | - | $ | - |
Natural Gas | $567,424 | 72,864 | MMBtu | $7.79 |
TOTAL ENERGY COSTS | $1,675,690 | |||
RECOMMENDED SAVINGS* | $339,736 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $80,970 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $177,870 Cost: $500,000 |
$106,139 | 1,682,034 | $71,731 | 9,894 | - | - |
$106,139 1,682,034 kWh |
$71,731 9,894 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2314 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT |
Savings: $30,131 Cost: $24,450 |
- | - | - | - | $30,131 | 3,868 |
- - kWh |
- - kW-months/year |
$30,131 3,868 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $31,322 Cost: $95,000 |
$31,322 | 496,395 | - | - | - | - |
$31,322 496,395 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1224 REPLACE BOILER |
Savings: $34,455 Cost: $6,500 |
$(-5,939) | (-94,118) | - | - | $40,394 | 5,179 |
$(-5,939) (-94,118) kWh |
- - kW-months/year |
$40,394 5,179 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $19,294 Cost: $2,400 |
$19,294 | 305,766 | - | - | - | - |
$19,294 305,766 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $27,723 Cost: - |
$17,029 | 269,869 | $10,694 | 1,475 | - | - |
$17,029 269,869 kWh |
$10,694 1,475 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $6,035 Cost: $855 |
$6,035 | 95,648 | - | - | - | - |
$6,035 95,648 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7493 USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES |
Savings: $6,282 Cost: $14,000 |
- | - | - | - | $6,282 | 806 |
- - kWh |
- - kW-months/year |
$6,282 806 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,822 Cost: $6,100 |
$2,858 | 45,288 | $964 | 133 | - | - |
$2,858 45,288 kWh |
$964 133 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,379 Cost: $1,500 |
$1,379 | 21,861 | - | - | - | - |
$1,379 21,861 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,423 Cost: $1,600 |
$1,423 | 22,559 | - | - | - | - |
$1,423 22,559 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $339,736 Cost: $652,405 |
$179,540 | 2,845,302 | $83,389 | 11,502 | $76,807 | 9,853 | $179,540 2,845,302 kWh |
$83,389 11,502 kW-months/year |
$76,807 9,853 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $80,970 Cost: $32,950 |
$39,181 | 620,923 | $11,658 | 1,608 | $30,131 | 3,868 | $39,181 620,923 kWh |
$11,658 1,608 kW-months/year |
$30,131 3,868 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |