Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2016
Principal Product Investment casting
NAICS 331512 - Steel Investment Foundries
SIC 3324 - Steel Investment Foundries
Sales $100,000,000-$500,000,000
# of Employees 47
Plant Area (Sq.Ft.) 25,000
Annual Production 509,000 Pieces
Production Hrs. Annual 3,060
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $47,456 873,669 kWh $0.05
Electricity Demand $35,109 4,272 kW-months/year $8.22
Electricity Fees $16,761 - $ -
Natural Gas $8,549 1,594 MMBtu $5.36
TOTAL ENERGY COSTS $122,975
RECOMMENDED SAVINGS* $6,376 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.2313 USE BATCH FIRING WITH KILN "FURNITURE" SPECIFICALLY DESIGNED Savings:
$3,034
Cost:
$400
- - - - $3,034 566 -
-
kWh
-
-
kW-months/year
$3,034
566
MMBtu
02: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT Savings:
$1,302
Cost:
$4,004
- - - - $1,302 243 -
-
kWh
-
-
kW-months/year
$1,302
243
MMBtu
03: 2.1121 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING Savings:
$533
Cost:
$276
- - - - $533 99 -
-
kWh
-
-
kW-months/year
$533
99
MMBtu
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$548
Cost:
$318
$343 6,316 $205 25 - - $343
6,316
kWh
$205
25
kW-months/year
-
-
MMBtu
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$258
Cost:
$200
$159 2,924 $99 12 - - $159
2,924
kWh
$99
12
kW-months/year
-
-
MMBtu
06: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$481
Cost:
$320
$481 8,864 - - - - $481
8,864
kWh
-
-
kW-months/year
-
-
MMBtu
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$220
Cost:
$321
$137 2,531 $82 10 - - $137
2,531
kWh
$82
10
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$6,376
Cost:
$5,839
$1,120 20,635 $386 47 $4,869 908 $1,120
20,635
kWh
$386
47
kW-months/year
$4,869
908
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas