Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2016 |
Principal Product | Toner Cartridges & Small Electronic Devices |
NAICS | 333316 - Photographic and Photocopying Equipment Manufacturing |
SIC | 3577 - Computer Peripheral Equipment, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 190 |
Plant Area (Sq.Ft.) | 315,664 |
Annual Production | 4,800,000 Units |
Production Hrs. Annual | 2,080 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $117,613 | 2,099,114 | kWh | $0.06 |
Electricity Demand | $24,518 | 6,010 | kW-months/year | $4.08 |
Electricity Fees | $33,540 | - | $ | - |
Natural Gas | $52,253 | 8,965 | MMBtu | $5.83 |
TOTAL ENERGY COSTS | $235,250 | |||
RECOMMENDED SAVINGS* | $31,648 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $25,675 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $22,885 Cost: $59,248 |
$17,447 | 311,551 | $5,438 | 1,333 | - | - |
$17,447 311,551 kWh |
$5,438 1,333 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,510 Cost: $5,375 |
$2,510 | 44,824 | - | - | - | - |
$2,510 44,824 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,504 Cost: $1,270 |
$1,763 | 31,486 | $741 | 182 | - | - |
$1,763 31,486 kWh |
$741 182 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $910 Cost: - |
$640 | 11,433 | $269 | 66 | - | - |
$640 11,433 kWh |
$269 66 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $606 Cost: $2,250 |
$426 | 7,613 | $179 | 44 | - | - |
$426 7,613 kWh |
$179 44 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $869 Cost: $1,230 |
- | - | - | - | $869 | 149 |
- - kWh |
- - kW-months/year |
$869 149 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $428 Cost: $396 |
$313 | 5,590 | $115 | 28 | - | - |
$313 5,590 kWh |
$115 28 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $418 Cost: $1,015 |
$319 | 5,694 | $99 | 24 | - | - |
$319 5,694 kWh |
$99 24 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $280 Cost: $242 |
$253 | 4,512 | $27 | 7 | - | - |
$253 4,512 kWh |
$27 7 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $238 Cost: $576 |
$217 | 3,870 | $22 | 5 | - | - |
$217 3,870 kWh |
$22 5 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $31,648 Cost: $71,602 |
$23,888 | 426,573 | $6,891 | 1,689 | $869 | 149 | $23,888 426,573 kWh |
$6,891 1,689 kW-months/year |
$869 149 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $25,675 Cost: $64,865 |
$20,210 | 360,887 | $5,465 | 1,340 | - | - | $20,210 360,887 kWh |
$5,465 1,340 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |