Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2016
Principal Product Toner Cartridges & Small Electronic Devices
NAICS 333316 - Photographic and Photocopying Equipment Manufacturing
SIC 3577 - Computer Peripheral Equipment, Nec
Sales $100,000,000-$500,000,000
# of Employees 190
Plant Area (Sq.Ft.) 315,664
Annual Production 4,800,000 Units
Production Hrs. Annual 2,080
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $117,613 2,099,114 kWh $0.06
Electricity Demand $24,518 6,010 kW-months/year $4.08
Electricity Fees $33,540 - $ -
Natural Gas $52,253 8,965 MMBtu $5.83
TOTAL ENERGY COSTS $235,250
RECOMMENDED SAVINGS* $31,648 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $25,675
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$22,885
Cost:
$59,248
$17,447 311,551 $5,438 1,333 - - $17,447
311,551
kWh
$5,438
1,333
kW-months/year
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,510
Cost:
$5,375
$2,510 44,824 - - - - $2,510
44,824
kWh
-
-
kW-months/year
-
-
MMBtu
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,504
Cost:
$1,270
$1,763 31,486 $741 182 - - $1,763
31,486
kWh
$741
182
kW-months/year
-
-
MMBtu
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$910
Cost:
-
$640 11,433 $269 66 - - $640
11,433
kWh
$269
66
kW-months/year
-
-
MMBtu
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$606
Cost:
$2,250
$426 7,613 $179 44 - - $426
7,613
kWh
$179
44
kW-months/year
-
-
MMBtu
06: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$869
Cost:
$1,230
- - - - $869 149 -
-
kWh
-
-
kW-months/year
$869
149
MMBtu
07: 2.7134 USE PHOTOCELL CONTROLS Savings:
$428
Cost:
$396
$313 5,590 $115 28 - - $313
5,590
kWh
$115
28
kW-months/year
-
-
MMBtu
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$418
Cost:
$1,015
$319 5,694 $99 24 - - $319
5,694
kWh
$99
24
kW-months/year
-
-
MMBtu
09: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$280
Cost:
$242
$253 4,512 $27 7 - - $253
4,512
kWh
$27
7
kW-months/year
-
-
MMBtu
10: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$238
Cost:
$576
$217 3,870 $22 5 - - $217
3,870
kWh
$22
5
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$31,648
Cost:
$71,602
$23,888 426,573 $6,891 1,689 $869 149 $23,888
426,573
kWh
$6,891
1,689
kW-months/year
$869
149
MMBtu
TOTAL IMPLEMENTED Savings:
$25,675
Cost:
$64,865
$20,210 360,887 $5,465 1,340 - - $20,210
360,887
kWh
$5,465
1,340
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas