IAC logo
IAC Assessment: WM0104
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WM0104
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2017
Principal Product Development and Testing of Motorcycles and Components
NAICS 541380 - Testing Laboratories
SIC 8734 - Testing Laboratories
Sales <$500,000
# of Employees 760
Plant Area (Sq.Ft.) 400,000
Annual Production 1 Pieces
Production Hrs. Annual 6,000
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $599,546 9,656,337 kWh $0.06
Electricity Demand $325,689 24,091 kW-months/year $13.52
Electricity Fees $21,588 - $ -
Natural Gas $110,168 26,655 MMBtu $4.13
TOTAL ENERGY COSTS $1,056,991
RECOMMENDED SAVINGS* $120,572 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $18,173
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas Electricity Usage Electricity Demand Electricity Fees Natural Gas
$ kWh $ kW-months/year $ $ $ MMBtu
01: 2.3112 STORE HEATED/ COOLED WATER FOR USE DURING PEAK DEMAND PERIODS Savings:
$64,540
Cost:
$93,226
- - $46,247 3,420 $18,293 - - - -
-
kWh
$46,247
3,420
kW-months/year
$18,293
-
$
-
-
MMBtu
02: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$15,927
Cost:
$33,500
- - $15,927 1,178 - - - - -
-
kWh
$15,927
1,178
kW-months/year
-
-
$
-
-
MMBtu
03: 2.6241 REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY Savings:
$14,165
Cost:
-
- - - - - - $14,165 3,430 -
-
kWh
-
-
kW-months/year
-
-
$
$14,165
3,430
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$11,736
Cost:
$45,000
$1,317 21,216 - - - - $10,419 2,523 $1,317
21,216
kWh
-
-
kW-months/year
-
-
$
$10,419
2,523
MMBtu
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$4,008
Cost:
-
$1,737 27,975 $2,271 168 - - - - $1,737
27,975
kWh
$2,271
168
kW-months/year
-
-
$
-
-
MMBtu
06: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$7,607
Cost:
$650
$5,295 85,283 $2,312 171 - - - - $5,295
85,283
kWh
$2,312
171
kW-months/year
-
-
$
-
-
MMBtu
07: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$2,589
Cost:
$554
$1,386 22,320 $1,203 89 - - - - $1,386
22,320
kWh
$1,203
89
kW-months/year
-
-
$
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$120,572
Cost:
$172,930
$9,735 156,794 $67,960 5,026 $18,293 - $24,584 5,953 $9,735
156,794
kWh
$67,960
5,026
kW-months/year
$18,293
-
$
$24,584
5,953
MMBtu
TOTAL IMPLEMENTED Savings:
$18,173
Cost:
-
$1,737 27,975 $2,271 168 - - $14,165 3,430 $1,737
27,975
kWh
$2,271
168
kW-months/year
-
-
$
$14,165
3,430
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu
Electricity Usage Electricity Demand Electricity Fees Natural Gas Electricity Usage Electricity Demand Electricity Fees Natural Gas