Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2017 |
Principal Product | Development and Testing of Motorcycles and Components |
NAICS | 541380 - Testing Laboratories |
SIC | 8734 - Testing Laboratories |
Sales | <$500,000 |
# of Employees | 760 |
Plant Area (Sq.Ft.) | 400,000 |
Annual Production | 1 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $599,546 | 9,656,337 | kWh | $0.06 |
Electricity Demand | $325,689 | 24,091 | kW-months/year | $13.52 |
Electricity Fees | $21,588 | - | $ | - |
Natural Gas | $110,168 | 26,655 | MMBtu | $4.13 |
TOTAL ENERGY COSTS | $1,056,991 | |||
RECOMMENDED SAVINGS* | $120,572 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $18,173 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3112 STORE HEATED/ COOLED WATER FOR USE DURING PEAK DEMAND PERIODS |
Savings: $64,540 Cost: $93,226 |
- | - | $46,247 | 3,420 | $18,293 | - | - | - |
- - kWh |
$46,247 3,420 kW-months/year |
$18,293 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $15,927 Cost: $33,500 |
- | - | $15,927 | 1,178 | - | - | - | - |
- - kWh |
$15,927 1,178 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6241 REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY |
Savings: $14,165 Cost: - |
- | - | - | - | - | - | $14,165 | 3,430 |
- - kWh |
- - kW-months/year |
- - $ |
$14,165 3,430 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $11,736 Cost: $45,000 |
$1,317 | 21,216 | - | - | - | - | $10,419 | 2,523 |
$1,317 21,216 kWh |
- - kW-months/year |
- - $ |
$10,419 2,523 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $4,008 Cost: - |
$1,737 | 27,975 | $2,271 | 168 | - | - | - | - |
$1,737 27,975 kWh |
$2,271 168 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $7,607 Cost: $650 |
$5,295 | 85,283 | $2,312 | 171 | - | - | - | - |
$5,295 85,283 kWh |
$2,312 171 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $2,589 Cost: $554 |
$1,386 | 22,320 | $1,203 | 89 | - | - | - | - |
$1,386 22,320 kWh |
$1,203 89 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $120,572 Cost: $172,930 |
$9,735 | 156,794 | $67,960 | 5,026 | $18,293 | - | $24,584 | 5,953 | $9,735 156,794 kWh |
$67,960 5,026 kW-months/year |
$18,293 - $ |
$24,584 5,953 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $18,173 Cost: - |
$1,737 | 27,975 | $2,271 | 168 | - | - | $14,165 | 3,430 | $1,737 27,975 kWh |
$2,271 168 kW-months/year |
- - $ |
$14,165 3,430 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |