Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2017 |
Principal Product | Treat Wastewater |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | $1,000,000-$5,000,000 |
# of Employees | 5 |
Plant Area (Sq.Ft.) | 273,000 |
Annual Production | 80,001 Units |
Production Hrs. Annual | 8,760 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $94,095 | 1,854,454 | kWh | $0.05 |
Electricity Demand | $44,887 | 4,240 | kW-months/year | $10.59 |
Electricity Fees | $25,958 | - | $ | - |
Natural Gas | $16,710 | 3,153 | MMBtu | $5.30 |
TOTAL ENERGY COSTS | $331,650 | |||
RECOMMENDED SAVINGS* | $334,604 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,914 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (haz) | One-time Revenue or Avoided Cost | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (haz) | One-time Revenue or Avoided Cost | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $282,127 Cost: $836,828 |
- | - | - | - | - | - | $150,000 | 1,414,000 | - | - | $132,127 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$150,000 1,414,000 lb |
- - $ |
$132,127 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $27,888 Cost: $228,151 |
$27,888 | 452,000 | - | - | - | - | - | - | - | - | - | - |
$27,888 452,000 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $14,544 Cost: $42,400 |
$11,315 | 223,001 | $3,229 | 305 | - | - | - | - | - | - | - | - |
$11,315 223,001 kWh |
$3,229 305 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $3,705 Cost: $6,960 |
- | - | - | - | $3,705 | 699 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,705 699 MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,624 Cost: $1,590 |
$874 | 17,231 | $750 | 71 | - | - | - | - | - | - | - | - |
$874 17,231 kWh |
$750 71 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,520 Cost: - |
$967 | 19,060 | $553 | 52 | - | - | - | - | - | - | - | - |
$967 19,060 kWh |
$553 52 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,182 Cost: $1,400 |
$1,182 | 21,362 | - | - | - | - | - | - | - | - | - | - |
$1,182 21,362 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $817 Cost: $1,224 |
$635 | 12,520 | $182 | 17 | - | - | - | - | - | - | - | - |
$635 12,520 kWh |
$182 17 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $803 Cost: - |
$72 | 1,413 | - | - | $731 | 138 | - | - | - | - | - | - |
$72 1,413 kWh |
- - kW-months/year |
$731 138 MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $394 Cost: - |
- | - | - | - | - | - | - | - | $394 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$394 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $334,604 Cost: $1,118,553 |
$42,933 | 746,587 | $4,713 | 445 | $4,436 | 837 | $150,000 | 1,414,000 | $394 | - | $132,127 | - | $42,933 746,587 kWh |
$4,713 445 kW-months/year |
$4,436 837 MMBtu |
$150,000 1,414,000 lb |
$394 - $ |
$132,127 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,914 Cost: - |
$967 | 19,060 | $553 | 52 | - | - | - | - | $394 | - | - | - | $967 19,060 kWh |
$553 52 kW-months/year |
- - MMBtu |
- - lb |
$394 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (haz) | One-time Revenue or Avoided Cost | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (haz) | One-time Revenue or Avoided Cost | By-product Production |