Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2018 |
Principal Product | HVAC Eqiupment |
NAICS | 332322 - Sheet Metal Work Manufacturing |
SIC | 3564 - Blowers And Fans |
Sales | $50,000,000-$100,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 220,000 |
Annual Production | 1,137,498 Units |
Production Hrs. Annual | 2,000 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $90,459 | 1,750,367 | kWh | $0.05 |
Electricity Demand | $59,390 | 4,335 | kW-months/year | $13.70 |
Electricity Fees | $4,893 | - | $ | - |
Natural Gas | $48,734 | 9,665 | MMBtu | $5.04 |
TOTAL ENERGY COSTS | $213,516 | |||
RECOMMENDED SAVINGS* | $42,456 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $13,294 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $14,609 Cost: $72,000 |
$14,609 | 282,681 | - | - | - | - | - | - | - | - |
$14,609 282,681 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $3,191 Cost: $10,230 |
$3,191 | 61,752 | - | - | - | - | - | - | - | - |
$3,191 61,752 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,895 Cost: $14,722 |
$3,048 | 58,972 | $4,847 | 354 | - | - | - | - | - | - |
$3,048 58,972 kWh |
$4,847 354 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $7,112 Cost: $14,000 |
- | - | - | - | $7,112 | 1,413 | - | - | - | - |
- - kWh |
- - kW-months/year |
$7,112 1,413 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4153 USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER |
Savings: $3,017 Cost: $3,000 |
- | - | - | - | - | - | $3,017 | 1,006 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$3,017 1,006 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,729 Cost: $1,833 |
$908 | 17,564 | $659 | 48 | - | - | - | - | $162 | - |
$908 17,564 kWh |
$659 48 kW-months/year |
- - MMBtu |
- - Tgal |
$162 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $1,678 Cost: $3,960 |
- | - | - | - | $1,678 | 333 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,678 333 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1221 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES |
Savings: $1,597 Cost: $3,400 |
- | - | - | - | $1,597 | 317 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,597 317 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,233 Cost: $3,124 |
$475 | 9,212 | $758 | 55 | - | - | - | - | - | - |
$475 9,212 kWh |
$758 55 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $395 Cost: $720 |
$195 | 3,767 | $71 | 5 | - | - | - | - | $129 | - |
$195 3,767 kWh |
$71 5 kW-months/year |
- - MMBtu |
- - Tgal |
$129 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $42,456 Cost: $126,989 |
$22,426 | 433,948 | $6,335 | 462 | $10,387 | 2,063 | $3,017 | 1,006 | $291 | - | $22,426 433,948 kWh |
$6,335 462 kW-months/year |
$10,387 2,063 MMBtu |
$3,017 1,006 Tgal |
$291 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $13,294 Cost: $24,635 |
$4,150 | 80,303 | $5,577 | 407 | $3,275 | 650 | - | - | $291 | - | $4,150 80,303 kWh |
$5,577 407 kW-months/year |
$3,275 650 MMBtu |
- - Tgal |
$291 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | One-time Revenue or Avoided Cost |