IAC logo
IAC Assessment: WM0126
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WM0126
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2018
Principal Product Soy Sauce
NAICS 311991 - Perishable Prepared Food Manufacturing
SIC 2099 - Food Preparations, Nec
Sales $100,000,000-$500,000,000
# of Employees 200
Plant Area (Sq.Ft.) 700,000
Annual Production 30,000 Thousand Gallons
Production Hrs. Annual 8,760
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,586,162 32,636,800 kWh $0.05
Electricity Demand $872,950 63,719 kW-months/year $13.70
Electricity Fees $92,087 - $ -
Natural Gas $1,217,376 310,521 MMBtu $3.92
TOTAL ENERGY COSTS $3,768,575
RECOMMENDED SAVINGS* $176,465 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $15,165
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$95,648
Cost:
$66,000
- - - - $95,648 24,400 -
-
kWh
-
-
kW-months/year
$95,648
24,400
MMBtu
02: 2.1243 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER Savings:
$26,985
Cost:
$20,000
- - - - $26,985 6,884 -
-
kWh
-
-
kW-months/year
$26,985
6,884
MMBtu
03: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$14,198
Cost:
$48,500
$14,198 276,867 - - - - $14,198
276,867
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$10,475
Cost:
$8,650
$7,557 155,495 $2,918 213 - - $7,557
155,495
kWh
$2,918
213
kW-months/year
-
-
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$8,011
Cost:
$15,236
$5,779 118,908 $2,232 163 - - $5,779
118,908
kWh
$2,232
163
kW-months/year
-
-
MMBtu
06: 2.2113 REPAIR OR REPLACE STEAM TRAPS Savings:
$7,154
Cost:
$6,480
- - - - $7,154 1,825 -
-
kWh
-
-
kW-months/year
$7,154
1,825
MMBtu
07: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC Savings:
$7,029
Cost:
$1,710
- - - - $7,029 1,793 -
-
kWh
-
-
kW-months/year
$7,029
1,793
MMBtu
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$4,101
Cost:
$2,850
$2,958 60,873 $1,143 83 - - $2,958
60,873
kWh
$1,143
83
kW-months/year
-
-
MMBtu
09: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$2,864
Cost:
-
$778 15,996 $2,087 152 - - $778
15,996
kWh
$2,087
152
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$176,465
Cost:
$169,426
$31,270 628,139 $8,379 612 $136,816 34,902 $31,270
628,139
kWh
$8,379
612
kW-months/year
$136,816
34,902
MMBtu
TOTAL IMPLEMENTED Savings:
$15,165
Cost:
$21,716
$5,779 118,908 $2,232 163 $7,154 1,825 $5,779
118,908
kWh
$2,232
163
kW-months/year
$7,154
1,825
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas